Deuterium lamp (L2D2 lamp) L12307
Spectral distribution : 185 nm to 400 nm, Aperture diameter : 0.5 mm, Guaranteed life : 2000 h
Specifications
Series | L2-2000 |
---|---|
Electrode Structure | Standard |
Window Material | UV Glass |
Spectral Distribution (Short) | 185 nm |
Spectral Distribution (Long) | 400 nm |
Aperture Diameter *a | 0.5 mm |
Output Stability Drift Max. | +/- 0.3 %/h |
Output Stability Fluctuation (p-p) Typ. | 0.005 % |
Guaranteed Life *d | 2000 h |
Required Discharge Starting Voltage Min. | 400.0 V dc |
Anode Current | 300 +/- 30 mA dc |
Tube Drop Voltage Typ. | 80.0 V dc |
Filament Warm-up Voltage | 12 to 15 V dc, V ac |
Filament Warm-up Current Typ. | 0.5 to 0.55 A dc, A ac |
Filament Warm-up Time | 20 s |
Filament Operating Voltage | 0 (*1) V dc |
Filament Operating Current Typ. | 0 (*1) A dc |
Notes | (*1) During lamp operation a discharge current flows into the filament so no external power supply is needed to maintain the filament temperature. |
Deuterium lamp (L2D2 lamp) L12313
Spectral distribution : 185 nm to 400 nm, Aperture diameter : 0.5 mm, Guaranteed life : 2000 h
Specifications
Series | L2-2000 |
---|---|
Electrode Structure | Standard |
Window Material | UV Glass |
Spectral Distribution (Short) | 185 nm |
Spectral Distribution (Long) | 400 nm |
Aperture Diameter *a | 0.5 mm |
Output Stability Drift Max. | +/- 0.3 %/h |
Output Stability Fluctuation (p-p) Typ. | 0.005 % |
Guaranteed Life *d | 2000 h |
Required Discharge Starting Voltage Min. | 400.0 V dc |
Anode Current | 300 +/- 30 mA dc |
Tube Drop Voltage Typ. | 80.0 V dc |
Filament Warm-up Voltage | 3.0 V dc, V ac |
Filament Warm-up Current Typ. | 5 A dc, A ac |
Filament Warm-up Time | 20 s |
Filament Operating Voltage | 0 to 1 V dc |
Filament Operating Current Typ. | 0 to 1.8 A dc |
Deuterium lamp (L2D2 lamp) L12313-50
Spectral distribution : 185 nm to 400 nm, Aperture diameter : 0.5 mm, Guaranteed life : 2000 h
Specifications
Series | L2-2000 |
---|---|
Electrode Structure | Standard |
Window Material | UV Glass |
Spectral Distribution (Short) | 185 nm |
Spectral Distribution (Long) | 400 nm |
Aperture Diameter *a | 0.5 mm |
Output Stability Drift Max. | +/- 0.3 %/h |
Output Stability Fluctuation (p-p) Typ. | 0.005 % |
Guaranteed Life *d | 2000 h |
Required Discharge Starting Voltage Min. | 400 V dc |
Anode Current | 300 +/- 30 mA dc |
Tube Drop Voltage Typ. | 80.0 V dc |
Filament Warm-up Voltage | 3.0 V dc, V ac |
Filament Warm-up Current Typ. | 5 A dc, A ac |
Filament Warm-up Time | 20 s |
Filament Operating Voltage | 0 to 1 V dc |
Filament Operating Current Typ. | 0 to 1.8 A dc |
Deuterium lamp (L2D2 lamp) L6301
Spectral distribution : 185 nm to 400 nm, Aperture diameter : 0.5 mm, Guaranteed life : 2000 h
Specifications
Series | L2-2000 |
---|---|
Electrode Structure | Standard |
Window Material | UV Glass |
Spectral Distribution (Short) | 185 nm |
Spectral Distribution (Long) | 400 nm |
Aperture Diameter *a | 0.5 mm |
Output Stability Drift Max. | +/- 0.3 %/h |
Output Stability Fluctuation (p-p) Typ. | 0.005 % |
Guaranteed Life *d | 2000 h |
Required Discharge Starting Voltage Min. | 400.0 V dc |
Anode Current | 300 +/- 30 mA dc |
Tube Drop Voltage Typ. | 80.0 V dc |
Filament Warm-up Voltage | 2.5 +/- 0.25 V dc, V ac |
Filament Warm-up Current Typ. | 4 A dc, A ac |
Filament Warm-up Time | 20 s |
Filament Operating Voltage | 1.0 +/- 0.1 V dc |
Filament Operating Current Typ. | 1.8 A dc |
Deuterium lamp (L2D2 lamp) L6301-50
Spectral distribution : 185 nm to 400 nm, Aperture diameter : 0.5 mm, Guaranteed life : 2000 h
Specifications
Series | L2-2000 |
---|---|
Electrode Structure | Standard |
Window Material | UV Glass |
Spectral Distribution (Short) | 185 nm |
Spectral Distribution (Long) | 400 nm |
Aperture Diameter *a | 0.5 mm |
Output Stability Drift Max. | +/- 0.3 %/h |
Output Stability Fluctuation (p-p) Typ. | 0.005 % |
Guaranteed Life *d | 2000 h |
Required Discharge Starting Voltage Min. | 400.0 V dc |
Anode Current | 300 +/- 30 mA dc |
Tube Drop Voltage Typ. | 80.0 V dc |
Filament Warm-up Voltage | 2.5 +/- 0.25 V dc, V ac |
Filament Warm-up Current Typ. | 4 A dc, A ac |
Filament Warm-up Time | 20 s |
Filament Operating Voltage | 1.0 +/- 0.1 V dc |
Filament Operating Current Typ. | 1.8 A dc |
Deuterium lamp (L2D2 lamp) L6303
Spectral distribution : 185 nm to 400 nm, Aperture diameter : 0.5 mm, Guaranteed life : 2000 h
Specifications
Series | L2-2000 |
---|---|
Electrode Structure | Standard |
Window Material | UV Glass |
Spectral Distribution (Short) | 185 nm |
Spectral Distribution (Long) | 400 nm |
Aperture Diameter *a | 0.5 mm |
Output Stability Drift Max. | +/- 0.3 %/h |
Output Stability Fluctuation (p-p) Typ. | 0.005 % |
Guaranteed Life *d | 2000 h |
Required Discharge Starting Voltage Min. | 400.0 V dc |
Anode Current | 300 +/- 30 mA dc |
Tube Drop Voltage Typ. | 80.0 V dc |
Filament Warm-up Voltage | 2.5 +/- 0.25 V dc, V ac |
Filament Warm-up Current Typ. | 4 A dc, A ac |
Filament Warm-up Time | 20 s |
Filament Operating Voltage | 1.7 +/- 0.2 V dc |
Filament Operating Current Typ. | 3.3 A dc |
Deuterium lamp (L2D2 lamp) L6307
Spectral distribution : 185 nm to 400 nm, Aperture diameter : 0.5 mm, Guaranteed life : 2000 h
Specifications
Series | L2-2000 |
---|---|
Electrode Structure | Standard |
Window Material | UV Glass |
Spectral Distribution (Short) | 185 nm |
Spectral Distribution (Long) | 400 nm |
Aperture Diameter *a | 0.5 mm |
Output Stability Drift Max. | +/- 0.3 %/h |
Output Stability Fluctuation (p-p) Typ. | 0.005 % |
Guaranteed Life *d | 2000 h |
Required Discharge Starting Voltage Min. | 400.0 V dc |
Anode Current | 300 +/- 30 mA dc |
Tube Drop Voltage Typ. | 80.0 V dc |
Filament Warm-up Voltage | 10 +/- 1 V dc, V ac |
Filament Warm-up Current Typ. | 0.8 A dc, A ac |
Filament Warm-up Time | 20 s |
Filament Operating Voltage | 2.5 to 6.0 V dc |
Filament Operating Current Typ. | 0.3 to 0.6 A dc |
Deuterium lamp (L2D2 lamp) L6309
Spectral distribution : 185 nm to 400 nm, Aperture diameter : 0.5 mm, Guaranteed life : 2000 h
Specifications
Series | L2-2000 |
---|---|
Electrode Structure | Standard |
Window Material | UV Glass |
Spectral Distribution (Short) | 185 nm |
Spectral Distribution (Long) | 400 nm |
Aperture Diameter *a | 0.5 mm |
Output Stability Drift Max. | +/- 0.3 %/h |
Output Stability Fluctuation (p-p) Typ. | 0.005 % |
Guaranteed Life *d | 2000 h |
Required Discharge Starting Voltage Min. | 400.0 V dc |
Anode Current | 300 +/- 30 mA dc |
Tube Drop Voltage Typ. | 80.0 V dc |
Filament Warm-up Voltage | 10 +/- 1 V dc, V ac |
Filament Warm-up Current Typ. | 1.2 A dc, A ac |
Filament Warm-up Time | 20 s |
Filament Operating Voltage | 7.0 +/- 0.5 V dc |
Filament Operating Current Typ. | 1 A dc |
Deuterium lamp (L2D2 lamp) L7296
Spectral distribution : 160 nm to 400 nm, Aperture diameter : 0.5 mm, Guaranteed life : 2000 h
Specifications
Series | L2-2000 |
---|---|
Electrode Structure | Standard |
Window Material | Synthetic Silica |
Spectral Distribution (Short) | 160 nm |
Spectral Distribution (Long) | 400 nm |
Aperture Diameter *a | 0.5 mm |
Output Stability Drift Max. | +/- 0.3 %/h |
Output Stability Fluctuation (p-p) Typ. | 0.005 % |
Guaranteed Life *d | 2000 h |
Required Discharge Starting Voltage Min. | 400.0 V dc |
Anode Current | 300 +/- 30 mA dc |
Tube Drop Voltage Typ. | 80.0 V dc |
Filament Warm-up Voltage | 10 +/- 1 V dc, V ac |
Filament Warm-up Current Typ. | 1.2 A dc, A ac |
Filament Warm-up Time | 20 s |
Filament Operating Voltage | 7.0 +/- 0.5 V dc |
Filament Operating Current Typ. | 1 A dc |
Deuterium lamp (L2D2 lamp) L7296-50
Spectral distribution : 160 nm to 400 nm, Aperture diameter : 0.5 mm, Guaranteed life : 2000 h
Specifications
Series | L2-2000 |
---|---|
Electrode Structure | Standard |
Window Material | Synthetic Silica |
Spectral Distribution (Short) | 160 nm |
Spectral Distribution (Long) | 400 nm |
Aperture Diameter *a | 0.5 mm |
Output Stability Drift Max. | +/- 0.3 %/h |
Output Stability Fluctuation (p-p) Typ. | 0.005 % |
Guaranteed Life *d | 2000 h |
Required Discharge Starting Voltage Min. | 400.0 V dc |
Anode Current | 300 +/- 30 mA dc |
Tube Drop Voltage Typ. | 80.0 V dc |
Filament Warm-up Voltage | 10 +/- 1 V dc, V ac |
Filament Warm-up Current Typ. | 1.2 A dc, A ac |
Filament Warm-up Time | 20 s |
Filament Operating Voltage | 7.0 +/- 0.5 V dc |
Filament Operating Current Typ. | 1 A dc |
Deuterium lamp (L2D2 lamp) L9030
Spectral distribution : 160 nm to 400 nm, Aperture diameter : 0.5 mm, Guaranteed life : 2000 h
Specifications
Series | L2-2000 |
---|---|
Electrode Structure | See-through |
Window Material | Synthetic Silica |
Spectral Distribution (Short) | 160 nm |
Spectral Distribution (Long) | 400 nm |
Aperture Diameter *a | 0.5 mm |
Output Stability Drift Max. | +/- 0.3 %/h |
Output Stability Fluctuation (p-p) Typ. | 0.005 % |
Guaranteed Life *d | 2000 h |
Required Discharge Starting Voltage Min. | 400.0 V dc |
Anode Current | 300 +/- 30 mA dc |
Tube Drop Voltage Typ. | 80.0 V dc |
Filament Warm-up Voltage | 2.5 +/- 0.25 V dc, V ac |
Filament Warm-up Current Typ. | 4 A dc, A ac |
Filament Warm-up Time | 20 s |
Filament Operating Voltage | 1.0 +/- 0.1 V dc |
Filament Operating Current Typ. | 1.8 A dc |
Deuterium lamp (L2d2 lamp) L9030-50
Spectral distribution : 160 nm to 400 nm, Aperture diameter : 0.5 mm, Guaranteed life : 2000 h
Specifications
Series | L2-2000 |
---|---|
Electrode Structure | See-through |
Window Material | Synthetic Silica |
Spectral Distribution (Short) | 160 nm |
Spectral Distribution (Long) | 400 nm |
Aperture Diameter *a | 0.5 mm |
Output Stability Drift Max. | +/- 0.3 %/h |
Output Stability Fluctuation (p-p) Typ. | 0.005 % |
Guaranteed Life *d | 2000 h |
Required Discharge Starting Voltage Min. | 400.0 V dc |
Anode Current | 300 +/- 30 mA dc |
Tube Drop Voltage Typ. | 80.0 V dc |
Filament Warm-up Voltage | 2.5 +/- 0.25 V dc, V ac |
Filament Warm-up Current Typ. | 4 A dc, A ac |
Filament Warm-up Time | 20 s |
Filament Operating Voltage | 1.0 +/- 0.1 V dc |
Filament Operating Current Typ. | 1.8 A dc |
Deuterium lamp (X2D2 lamp) L10804
Spectral distribution : 185 nm to 400 nm, Aperture diameter : 0.5 mm, Guaranteed life : 2000 h
Specifications
Series | X2D2 |
---|---|
Electrode Structure | See-through |
Window Material | UV Glass |
Spectral Distribution (Short) | 185 nm |
Spectral Distribution (Long) | 400 nm |
Aperture Diameter *a | 0.5 mm |
Output Stability Drift Max. | +/- 0.3 %/h |
Output Stability Fluctuation (p-p) Typ. | 0.005 % |
Guaranteed Life *d | 2000 h |
Required Discharge Starting Voltage Min. | 400.0 V dc |
Anode Current | 300 +/- 30 mA dc |
Tube Drop Voltage Typ. | 90.0 V dc |
Filament Warm-up Voltage | 2.5 +/- 0.25 V dc, V ac |
Filament Warm-up Current Typ. | 4 A dc, A ac |
Filament Warm-up Time | 20 s |
Filament Operating Voltage | 1.7 +/- 0.2 V dc |
Filament Operating Current Typ. | 3.3 A dc |
Deuterium lamp (X2D2 lamp) L10904
Spectral distribution : 160 to 400 nm, Aperture diameter : 0.5 mm, Guaranteed life : 2000 h
Specifications
Series | X2D2 |
---|---|
Electrode Structure | See-through |
Window Material | Synthetic Silica |
Spectral Distribution (Short) | 160 nm |
Spectral Distribution (Long) | 400 nm |
Aperture Diameter *a | 0.5 mm |
Output Stability Drift Max. | +/- 0.3 %/h |
Output Stability Fluctuation (p-p) Typ. | 0.005 % |
Guaranteed Life *d | 2000 h |
Required Discharge Starting Voltage Min. | 400.0 V dc |
Anode Current | 300 +/- 30 mA dc |
Tube Drop Voltage Typ. | 85.0 V dc |
Filament Warm-up Voltage | 2.5 +/- 0.25 V dc, V ac |
Filament Warm-up Current Typ. | 4 A dc, A ac |
Filament Warm-up Time | 20 s |
Filament Operating Voltage | 1.7 +/- 0.2 V dc |
Filament Operating Current Typ. | 3.3 A dc |
Deuterium lamp (X2D2 lamp) L9518
Spectral distribution : 185 nm to 400 nm, Aperture diameter : 0.5 mm, Guaranteed life : 2000 h
Specifications
Series | X2D2 |
---|---|
Electrode Structure | Standard |
Window Material | UV Glass |
Spectral Distribution (Short) | 185 nm |
Spectral Distribution (Long) | 400 nm |
Aperture Diameter *a | 0.5 mm |
Output Stability Drift Max. | +/- 0.3 %/h |
Output Stability Fluctuation (p-p) Typ. | 0.005 % |
Guaranteed Life *d | 2000 h |
Required Discharge Starting Voltage Min. | 400.0 V dc |
Anode Current | 300 +/- 30 mA dc |
Tube Drop Voltage Typ. | 90.0 V dc |
Filament Warm-up Voltage | 2.5 +/- 0.25 V dc, V ac |
Filament Warm-up Current Typ. | 4 A dc, A ac |
Filament Warm-up Time | 20 s |
Filament Operating Voltage | 1.7 +/- 0.2 V dc |
Filament Operating Current Typ. | 3.3 A dc |
Deuterium lamp (X2D2 lamp) L9519
Spectral distribution : 185 nm to 400 nm, Aperture diameter : 0.5 mm, Guaranteed life : 2000 h
Specifications
Series | X2D2 |
---|---|
Electrode Structure | Standard |
Window Material | Synthetic Silica |
Spectral Distribution (Short) | 160 nm |
Spectral Distribution (Long) | 400 nm |
Aperture Diameter *a | 0.5 mm |
Output Stability Drift Max. | +/- 0.3 %/h |
Output Stability Fluctuation (p-p) Typ. | 0.005 % |
Guaranteed Life *d | 2000 h |
Required Discharge Starting Voltage Min. | 400.0 V dc |
Anode Current | 300 +/- 30 mA dc |
Tube Drop Voltage Typ. | 85.0 V dc |
Filament Warm-up Voltage | 2.5 +/- 0.25 V dc, V ac |
Filament Warm-up Current Typ. | 4 A dc, A ac |
Filament Warm-up Time | 20 s |
Filament Operating Voltage | 1.7 +/- 0.2 V dc |
Filament Operating Current Typ. | 3.3 A dc |
Deuterium lamp (X2D2 lamp) L9841
Spectral distribution : 115 nm to 400 nm, Aperture diameter : 0.5 mm, Guaranteed life : 2000 h
Specifications
Series | X2D2 |
---|---|
Electrode Structure | Standard |
Window Material | MgF2 |
Spectral Distribution (Short) | 115 nm |
Spectral Distribution (Long) | 400 nm |
Aperture Diameter *a | 0.5 mm |
Output Stability Drift Max. | +/- 0.3 %/h |
Output Stability Fluctuation (p-p) Typ. | 0.005 % |
Guaranteed Life *d | 2000 h |
Required Discharge Starting Voltage Min. | 400.0 V dc |
Anode Current | 300 +/- 30 mA dc |
Tube Drop Voltage Typ. | 85.0 V dc |
Filament Warm-up Voltage | 2.5 +/- 0.25 V dc, V ac |
Filament Warm-up Current Typ. | 4 A dc, A ac |
Filament Warm-up Time | 20 s |
Filament Operating Voltage | 1.7 +/- 0.2 V dc |
Filament Operating Current Typ. | 3.3 A dc |
Si photodiode S12497
A scintillator can be mounted directly on the chip.
The S12497 is a Si photodiode suitable for non-destructive inspection of baggage and the like and general industrial measurement. As it is a back-illuminated photodiode, photosensitive area does not have wires, and therefore a scintillator can be mounted directly on the photodiode.
Features
- Spectral response range : 400 to 1100 nm
- Photosensitive area: 9.5 × 9.5 mm - Easy scintillator mounting
Notice
Before using this product, always read “Unsealed products / Precautions” described below.
Specifications
Photosensitive area | 9.5 × 9.5 mm |
---|---|
Number of elements | 1 |
Package | PWB with pins |
Cooling | Non-cooled |
Reverse voltage (max.) | 10 V |
Spectral response range | 400 to 1100 nm |
Peak sensitivity wavelength (typ.) | 920 nm |
Photosensitivity (typ.) | 0.57 A/W |
Dark current (max.) | 200 pA |
Rise time (typ.) | 15 μs |
Terminal capacitance (typ.) | 950 pF |
Measurement condition | Typ. Ta=25 ℃, unless otherwise noted, Photosensitivity: λ=920 nm, Dark current: VR=10 mV, Terminal capacitance: VR=0 V, f=10 kHz |
Si photodiode S12498
A scintillator can be mounted directly on the chip.
The S12498 is a Si photodiode suitable for non-destructive inspection of baggage and the like and general industrial measurement. As it is a back-illuminated photodiode, photosensitive area does not have wires, and therefore a scintillator can be mounted directly on the photodiode.
Features
- Spectral response range : 400 to 1100 nm
- Photosensitive area: 6.0 × 6.0 mm - Easy scintillator mounting
Notice
Before using this product, always read “Unsealed products / Precautions” described below.
Specifications
Photosensitive area | 6.0 × 6.0 mm |
---|---|
Number of elements | 1 |
Package | PWB with pins |
Cooling | Non-cooled |
Reverse voltage (max.) | 10 V |
Spectral response range | 400 to 1100 nm |
Peak sensitivity wavelength (typ.) | 920 nm |
Photosensitivity (typ.) | 0.57 A/W |
Dark current (max.) | 150 pA |
Rise time (typ.) | 15 μs |
Terminal capacitance (typ.) | 380 pF |
Measurement condition | Typ. Ta=25 ℃, unless otherwise noted, Photosensitivity: λ=920 nm, Dark current: VR=10 mV, Terminal capacitance: VR=0 V, f=10 kHz |
Si photodiode S12915-1010R
For visible to IR, general-purpose photometry
S12915 series have high sensitivity in the visible range to near IR.
They provide higher sensitivity than the S2387 series and can be used in high-humidity environments.
Features
- High sensitivity in visible to infrared range
- Low dark current
- High linearity
Specifications
Constitution | NEW | Conventional product | Unit |
---|---|---|---|
Type no. | S12915-1010R | S2387-1010R | - |
Window material | Plastic potting | - | |
Package | 15 × 16.5 | mm | |
Photosensitive area size | 10 × 10 | mm | |
Effective photosensitive area | 100 | mm2 | |
Reverse voltage Max. | 30 | V | |
Operating temperature | -20 ~ +60 | ℃ | |
Storage temperature | -20 ~ +80 | ℃ | |
Spectral response range | 340 ~ 1100 | nm | |
Peak sensitivity wavelength | 960 | nm | |
Photosensitivity Typ. | 0.64 | 0.58 | A/W |
Short circuit current Typ. | 95 | 91 | μA |
Dark current Max. | 200 | pA | |
Temp. coefficient of ID | 1.12 | times/℃ | |
Rise time Typ. | 33 | μs | |
Terminal capacitance Typ. | 13000 | 12000 | pF |
Shunt resistance Typ. | 5 | GΩ | |
Noise equivalent power | 2.8 × 10-15 | 3.1 × 10-15 | W/Hz1/2 |
Measurement conditions | Typ. Ta=25 °C, unless otherwise noted, Dark current: VR=10 mV, Rise time: VR=0 V, Shunt resistance: R=10 mV, Noise equivalent power: VR=0 V |
DR3900 Laboratory Spectrophotometer for water analysis
This photometer system is designed to deliver accurate results by supporting the operator with each step he is doing:
• Sample preparation: reduced handling steps, precise dosing
• Sample analysis: automatic test recognition, expiration date check etc.
• Documentation of results: versatile data management, control cards
With your daily routine of water analysis in mind the DR3900 spectrophotometer is optimised for safe processes and meaningful reports. Control-parameters like Ammonium, COD, Phosphate, Nitrogen and many others are easy to perform. The handling of tests and photometer is well designed to avoid any errors in your water analysis.
This instrument connects to Claros, Hach’s innovative Water Intelligence System, enabling you to seamlessly connect and manage instruments, data, and process – anywhere, anytime. The result is greater confidence in your data and improved efficiency in your operations. To unlock the full potential of Claros, insist on Claros Enabled instruments.
Incubation/Inactivation Bath
- Large high-contrast TFT-colour display with clear readout of all process data.
- Microprocessor-controlled temperature regulation.
- Excellent temperature constancy: ± 0.1 °C temporal at 50 °C.
- Soft-touch keys with characteristic symbols.
- Setting and displaying of temperature values in 0.1 °C increments as well as timer values in hours (h) and minutes (min).
- Timer with three functions:
> Switch-on delay of temperature control 0:00 to 999:59 h:min.
> Operating time after expiry of switch-on delay from 0:01 to 999:59 h:min
or continuous.
> Operating time after expiry of switch-on delay and reaching the set point
temperature from 0:01 to 999:59 h:min or continuous operation. - Separate menu items: temperature limits min/max, over/under temperature alarm up to +/- 10 K, switchover °C/°F and for a process-dependent temperature adjustment.
- Visual and acoustic alarm in case of water shortage, over/under temperature and sensor break/short circuit.
- Electronic monitoring; in case of fault, cause is reported on display.
- Two independently working over-temperature protections.
- Heating element, bath interior, cover, lid and perforated tray made of stainless steel.
- Thermal insulating and double-walled arched lid prevents twisting and dropping back of condensed water into the test tubes.
- Corrosion proof exterior housing made of electrolytically galvanised sheet steel, powder-coated.
- Lid and perforated tray included as standard scope of supply.
- Drain cock at the back of the bath.
- The pictured accessories are not included in the unit's standard scope of supply.
Technical details
|
|
Temperature range
|
approx. 5 °C above ambient temperature to +100 °C (boiling mode)
|
Temperature range
(operation with water level regulator) |
approx. 3 °C above tap water temperature to +100 °C
|
Capacity
|
approx. 16 l
|
Interior dimensions
(W x D x working height) |
400 x 245 x 165 mm
|
Exterior dimensions
(W x D x H) |
500 x 440 x 275 mm
|
Electrical connection
|
230 V / 50...60 Hz / 1.5 kW *
|
Net / gross weight
|
approx. 13.3 / 15.2 kgs
|
Packing volume
|
approx. 0.149 m3
|
Kjeldahl Digestion ststem SH420F
Hanon SH420F Kjeldahl Digestion ststem adopts globally advanced high-temperature infrared t radiation heating technology and microprocessor control platform, boasts accurate temperature control and quick temperature rise. It has two kinds of temperature rise mode: linear and curve temperature rise mode, and offers 20 digestion programs for control of temperature rise curves.
Hanon neutralization system has many functions such as triple filtration, condensate recovery of exhaust gas, filtration and neutralization device. The product adopts high-quality Anticorrosive Pumps, low noise, strong suction, reduce exhaust emissions,eco-friendly.
Characteristics:
- 20 positions, enhance working efficiency rapidly.
- Graphite block have longer life after special anti-oxidation processing and heating more uniform.
- It adopt advanced insulation technology, eco-friendly, reduce energy intensity maximum limitedly.
- Corrosion-resistant design.
- It adopt advanced PID temperature control technology, high accuracy heating up to 400℃ only cost 25minutes.
- Temperature control model: Program control, curve and linear temperature rise.
- Multi-protection, Over-current protection, high temperature warning, overload protection.
- It adopts 5.7” color screen, easy for use.
- It can pretreat for microwave digestion or removing acid after digestion.
- Standard configuration with waste gas collection hood.
MP490 Melting Point Apparatus
Hanon MP490 Automatic Melting Point Apparatus perfectly integrate video technology into melting point measuring.It not only provides users with reliable melting point test result, but also intuitively displays temperature curve and real-time video image, and achieves the function of save, replay the video etc. It provides better help for users to observe melting process of sample.
The instrument can be widely used in the chemical industry and pharmaceutical research. It is the essential equipment for production of drugs, spices, dyes, and measurement of other organic crystal substances,especially for dark color sample.
Characteristic
China first-created Automatic Video Melting Point Apparatus perfectly integrate video technology into melting point measuring.
Innovative double true-color VGA touch screen is easy for operation and observation.
Vast amounts of storage space, can achieve 300 minutes of continuous shooting or nearly 10000 photos storage.
0.1℃--20.0℃ linear temperature rise design is satisfactory for varied temperature rise options.
Store up 80 sets of customers experimental method, 40 sets atlas and test data.
Data can be printed. It’s completely in line with pharmacopeia and GLP requirements.
Networking Tool Kit
- Mobile Phone Tool Kit
- Tone Generator& Probe Kit
- Digital Multimeter
- Modular Crimping Toolfor 8P / 6P
- Soldering Iron 30W
- Soldering iron Stand
Oil Free Vacuum Pump Rocker 300
Features :
◆ No air pollution, maintenance free
Rocker series pumps are driven by Piston, without the need of lubricant, regular oil changes and maintenance; with no oil pollution.
◆ Prote™ overflow protection
Rocker series pumps are equipped with Prote™ overflow protection which can prevent a large amount of liquid from
being sucked into the pump.
◆ Moisture trap with filter cartridge
Rocker series pumps are equipped with filter cartridge in air inlet to filter particle and moisture to prolong the life of pump.
◆ Vacuum regulator
Rocker series pumps are equipped with vacuum regulator to adjust vacuum.
◆ Thermal protection device
Every motor of Rocker series pumps has a built-in thermal protection device to shut off the pump automatically when overheated and then resume working when the temperature cools down.
International certification :
◆ CE certification
◆ CSA certification
◆ IP 30 protection class
◆ RoHS certification
Applications :
◆ Filtration for microbiology test
◆ Air sampling
◆ Suspended solid test
◆ Vacuum filtration
Ordering Information :
◆ 167300-11(22)
Rocker 300, Vacuum Pump
AC110V, 60Hz (AC220V, 50Hz)
PRESICION ANSI 5A CTS CURRENT TRANSFORMER SUPPLIER
he dry type current transformers GFLZZ0954-10E are cast in epoxy resin insulated with big surface creepage distance and are excellent in anti-pollution and humidity protection. With high grade accuracy, it is suitable for protection against large short-circuit current, secondary current output 1A or 5A. The performances of the products meet standards IEC60044-1, IEC61869-2 and ANSI/IEEE C57.13.
PARAMETERS
Technical parameters | |
---|---|
Standards | IEC60044; IEC 61869; ANSI/IEEE C57.13 |
Rated primary current | 5-1250A |
Rated load | ≤15VA |
Rated frequency | 50Hz or 60Hz |
Rated secondary current | 5A or 1A |
Rated short-time thermal current | 140kA, 1S |
Rated dynamic current | 350KA |
Rated insulation level | 12/42/75KV |
FS | ≤10 |
Mechanical parameters | |
Material | Epoxy resin |
Weight (kg) | 32 |
Operating conditions | |
Operating temperature | -25°C to +55°C |
Daily average temp | <+40°C |
Storage temperature | -40°C to +70°C |
Altitude | <1000 meters |
Condition | No existence of severely begrimed, erosive and radioactive gas in the air. Permission of long-term operation under rated current. |
TECHNICAL PARAMETERS
Ratied Primary Current(A) | Class Combination | Accuracy class and Rated output(VA) | Short-time thermal current(kA/S) | Rated dynamic current(kA) | |
---|---|---|---|---|---|
0.5 | 10P10 | ||||
5-150 |
0.2(S)/10P10 0.5/10P10 |
10 | 15 | 150 I1n | 375 I1n |
200 | 36 | 90 | |||
300 | 45 | 100 | |||
400-600 | 63 | 150 | |||
800-1000 | 100 | 250 | |||
1250 | 140 | 350 |
Shaking Water Bath
- Microprocessor-controlled temperature regulation.
- Excellent temperature constancy: ± 0.1 °C temporal at 50 °C.
- Optimum temperature distribution throughout the whole bath interior.
- Digital temperature readout and setting via LED display, in steps of 0.1 °C.
- Soft-touch keys with characteristic symbols.
- Electronic monitoring; in case of fault, cause is reported on display.
- Two independently working over-temperature protections.
- Maintenance-free and low-wear shaking mechanism, continuously adjustable electronic speed control, gentle start-up.
- Constant speed, independent of load.
- The shaking device is guided on corrosion-resistant special ball bearings.
- Easily removable shaking rack.
- Thermal insulating and double-walled arched lid prevents twisting and dropping back of condensed water into the test tubes.
- Bath interior and shaking rack made of stainless steel.
- Corrosion proof exterior housing made of electrolytically galvanised sheet steel, powder-coated.
- Drain cock at the back of the bath.
- The pictured accessories are not included in the unit's standard scope of supply.
Technical details
|
|
Temperature range
|
approx. 5 °C above ambient temperature to +99.9 °C
|
Temperature range
(operation with water level regulator) |
approx. 3 °C above tap water temperature to +99.9 °C
|
Capacity
|
approx. 20 l
|
Shaking motion
|
reciprocating, with on / off switch
|
Shaking frequency
|
from 10 - 250 rpm
|
Shaking amplitude
|
22 mm
|
Working height of bath
(including lid) |
190 mm (above bottom of shaking rack)
|
Max. water level above shaking rack / tray
|
105 mm / 90 mm
|
Inner dimensions
(W x D x H) |
450 x 300 x 160 mm
|
Exterior dimensions
(W x D x H) |
715 x 520 x 330 mm
|
Electrical connection
|
230 V / 50...60 Hz / 1.5 kW *
|
Net / gross weight
|
28.0 / 32.0 kgs
|
Packing volume
|
approx. 0.29 m3
|
SOX606 Fat Analyzer
SOX606 Automatic Soxhlet Extractor, designed based on the Soxhlet extraction principle with weight method to determine the fat content. It has five extraction methods to meet different demands from customer. The whole metal heating module, heating up fast, good effect, low power consumption; access to all-round water temperature, flow control, environmental protection more economical; built-in ether leak detection device to ensure experimental safety. It is widely used in agricultural/ food /chemical /environment and other areas, especially for the drug ,soil, sludge,cleaner and other substances in the extraction of soluble organic compounds.
Automatic extraction
One touch to start extraction, lifting, pre-heating, extraction, dilution, solvent recovery automatically.
In-built 5 unique methods of extraction, handy operation.
Include Soxhlet Extraction, Soxhlet Hot Extraction, Continue Flow Extractioin, Hot Extraction, CH Standard methods,
Apply to all organic solvents
Customized by glass and PTFE, which can block all impurities and possess high rate of accuracy, apply to all organic solvents, satisfying the requirements of users.
ECO- friendly and conservation
Full temperature and flow control for reduce consumption of condensed water.
STAINLESS STEEL BOX
STAINLESS STEEL BOX WITHOUT HANDLE
• Dimensions: 25 x 12 x h 6 cm
• Autoclavable at 125 °C
Sterilization containers
Standard container with one filter and non perforated bottom.
• Small model: 285 x 280 mm
• Height: 100 mm
• Non perforated bottom
• 1 filter
• Colour: grey
All containers are autoclavable at maximum 134°C and 2.2 bar.
10-Channel Classic Hotplate Magnetic Stirrer
Key Features
• Maintenance-free brushless DC motor
• Max speed 1100rpm
• Max.temperature 120°C
• Stainless steel work plate, covered with silicone cushion, provides the excellent performance of heating uniformity and skid resistance
100 MHz benchtop oscilloscope
Key indicators
- 100MHz oscilloscope
- Dual analog channel and one external trigger channel
- Real-time sampling rate 1GSa/s, equivalent sampling rate 50GSa/s
- 7" color TFT-LCD display, 8 x 18 grid display range
- Rich triggering functions: edge, pulse, video, slope, alternation
- 3 cursor measurement, 32 parameters automatic measurement function
- 5 kinds of mathematical operation functions, FFT operation split screen display function
- Unique digital filtering function: low pass, high pass, band pass, band stop
- Ultra-thin design, compact size, easy to carry
Applications
- Embedded electronic circuit design and debugging
- Industrial control, power measurement
- Investigate transient signals
- Manufacturing test, electrical function test
- Higher education and research
- Maintenance service
100mA milliohm meter
Key indicators
- 5 ranges are available, measuring from 0.1mΩ to 2000Ω
- Resolution 100μΩ to 1Ω (depending on the range)
- Accuracy: 0.3% ± 2cts
- Instantaneous or stable (60s) measurement
- If the voltage or current loop is not connected, the alarm will be given.
- HOLD function
- Low battery warning
- Electrical safety: 20V Cat.IV (IEC 61010
product description
100mA milliohm meter
Applications
- Winding resistance measurement of motors and small transformers
- Mechanical joint measurement
- Integrity detection of electric solder joints
10A micro-ohmmeter
Key indicators
- Measurement range from 1μΩ to 400Ω
- Test current optional: 10mA / 100mA / 1A / 10A
- Automatic measurement of measurement results in multi-point measurement mode
- Can store 99 sets of measurement data
product description
10A micro-ohmmeter, high precision, large range, suitable for various environments
Applications
- Ground junction measurement and continuity measurement
- Winding resistance measurement of motors and small transformers
- Contact resistance measurement of circuit breakers and switches
- Component measurement
16-Channel Classic Magnetic Stirrer,
Key Features
• A space saving unit with 16 stirring positions and 4 independent speed control channels
• A wide range of speed from 0 to 1100rpm
• High magnetic adhesion prevents stirrer spin bar out of control
• Stainless steel work plate, covered with silicone cushion, provides excellent performance of skid resistance
2 Channel Digital Oscilloscope DSO4000C Series
DSO4000C Series
2 Channel Digital Oscilloscope. 1 Channel Arbitrary/Function Waveform Generator. The Keys for osilloscope and waveform generator is seperated for convenient to operate it simultaneously. Oscilloscope: 200/100/70MHz Bandwidth, 1GSa/s Sample Rate. 25MHz Arbitrary waveform generator, 12 bits resolution, 200MHz DDS, 7 inch 64K color LCD display, Resolution 800x480.
Feature:
- 2 Channel Digital Oscilloscope + Arbitrary/Function Waveform Generator + Synchronizing Signal + External Trigger;
- The Keys for osilloscope and waveform generator is seperated for convenient to operate it simultaneously;
- Large and clear display (7 inch 64K color LCD display, Resolution 800x480), more clear and realistic waveform;
- Oscilloscope: 1GSa/s Sample Rate, 200/100/70MHz Bandwidth, more than 20 kinds of auto measurement functions;
- Powerful Trigger Function: Edge, Video, Pulse, Slope, Over time, Alternative;
- Arbitrary/Function Waveform Generator: 25MHz, 12 bits resolution, 200MHz DDS, Arbitrary wave/square wave/sine wave/triangle wave/trapezoidal wave/pulse wave/DC is easy to simulate transducer.
- Support SD card, VGA function (optional);
- Integrated USB Host, Support USB disk storage, USB interface/SD card system update.
200 MHz handheld oscilloscope
Key indicators
- 200MHz oscilloscope
- Oscilloscopes, multimeters, FFT analyzers, harmonic analyzers, and recorders
- RS-485, RS-232, Ethernet (OX7202-BUS / OX7204 BUS)
- 2.5 GS/s real-time sampling rate, 50GS/s equivalent sampling rate
- Memory depth 2500 points per channel (in oscilloscope mode), expandable to 50K
- 2 isolated channels, 600V Cat III, display 8 waveforms simultaneously
- 12-bit vertical resolution for deeper, more precise zooming
- 33 direct command keys and windowed menu interface
- 2 independent channels, 4000-point, TRMS, 200kHz digital multimeter function
- Color LCD touch screen oversized 320 x 240
- 2GB removable SD memory card
- Isolated USB interface capable of communicating with the SCPI protocol
- Multiple communication interfaces: RS-232, Ethernet (built-in WEB server)
- Smart probe with user-defined control buttons
- SX-METRO Software
- View the graph on the storage file
- Display real-time graphs on a PC
- Control the scope with a PC
- Output data and graphs in Excel format
product description
The oscilloscope OX 7202 is the ideal tool for laboratory testing and field testing.
The instrument is easy to operate and has direct access to all commonly used functions via 33 buttons. The OX 7202 is especially suitable for field use and is equipped with the latest patented “Plug and Play” probes. Each measurement channel is isolated and isolated from each other. It can be remotely controlled via a built-in WEB server and Ethernet. It's all in one, including a 2-channel TRMS multimeter.
Large 320 x 240 full color LCD display with detailed waveform detail and display of all measurements and functions. With the stylus, you can easily and quickly access the window menu: open, pull down or execute; the stylus can also directly act on graphical elements such as cursors, triggers and zooms.
Applications
- On-site repair - industrial or electronic
- Factory internal maintenance and repair
- Installation and operation monitoring
- Industrial process testing
- QC
- For R&D and laboratories - engineers or technicians
200 MHz handheld oscilloscope and fieldbus analyzer
Key indicators
- 200 MHz oscilloscope
- Oscilloscopes, multimeters, FFT analyzers, harmonic analyzers, and recorders
- Fieldbus Analyzer: KNX, DALI, CAN, LIN, FLEXRAY, AS-I,
- RS-485, RS-232, Ethernet (OX7202-BUS / OX7204 BUS)
- 2.5 GS/s real-time sampling rate, 50GS/s equivalent sampling rate
- Memory depth 2500 points per channel (in oscilloscope mode), expandable to 50K
- Four isolated channels, 600V Cat III, display up to eight waveforms simultaneously.
- 12-bit vertical resolution for deeper, more precise zooming
- 33 direct command keys and windowed menu interface
- 2 independent channels, 4000-point, TRMS, 200kHz digital multimeter function
- Color LCD touch screen oversized 320 x 240
- 2GB removable SD memory card
- Isolated USB interface capable of communicating with the SCPI protocol
- Multiple communication interfaces: RS-232, Ethernet (built-in WEB server)
- Smart probe with user-defined control buttons
- SX-METRO Software
- View the graph on the storage file
- Display real-time graphs on a PC
- Control the oscilloscope via PC
- Output data and graphs in Excel format
product description
The OX7204-BUS bus analysis oscilloscope can be used to perform on-site evaluation of bus technology integrity and to detect synchronization of bus electrical specifications. A series of communication lines consisting of fieldbus, electronic signals will be transmitted between two remote communication devices. Such a transmission system will replace the traditional 4-20 mA analog signal. At the site, various disturbances (deterioration of wiring, electromagnetic radiation, aging of insulators, leakage, etc.) may cause errors in signal transmission.
Applications
- On-site repair - industrial or electronic
- Factory internal maintenance and repair
- Installation and operation monitoring
- Industrial process testing
- QC
- For R&D and laboratories - engineers or technicians
- Bus bus analysis
2000A/5A WOUND TYPE MEDIUM VOLTAGE CURRENT TRANSFORMER
PARAMETERS
Technical parameters | |
---|---|
Standards | IEC60044; IEC 61869; ANSI/IEEE C57.13 |
Rated primary current | 5-3150A |
Rated load | ≤60VA |
Rated frequency | 50Hz or 60Hz |
Rated secondary current | 5A or 1A |
Rated short-time thermal current | 120kA, 1S |
Rated dynamic current | 200KA |
Rated insulation level | 12/42/75KV |
FS | ≤10 |
Mechanical parameters | |
Material | Epoxy resin |
Weight (kg) | 28 |
Operating conditions | |
Operating temperature | -25°C to +55°C |
Daily average temp | <+40°C |
Storage temperature | -40°C to +70°C |
Altitude | <1000 meters |
Condition | No existence of severely begrimed, erosive and radioactive gas in the air. Permission of long-term operation under rated current. |
TECHNICAL PARAMETERS
Ratied Primary Current(A) | Class Combination | Accuracy class and Rated output(VA) | Short-time thermal current(kA/S) |
Rated dynamic current(kA)
|
||||||
---|---|---|---|---|---|---|---|---|---|---|
0.2(S) | 0.5(S) | 10P10 | 10P15 | 10P20 | ||||||
5 | 0.2(S)/0.5(S) 0.2(S)/10P 0.5(S)/10P |
10 | 20 | 20 | 20 | 15 | 0.5 | 1* | 1.25 | 2.5* |
10 | 1 | 2* | 2.5 | 5* | ||||||
15 | 1.5 | 3* | 3.75 | 7.5* | ||||||
20 | 2 | 4* | 5 | 10* | ||||||
30 | 3 | 6* | 7.5 | 15* | ||||||
40 | 4 | 8* | 10 | 20* | ||||||
50 | 5 | 20* | 12.5 | 50* | ||||||
75 | 7.5 | 31.5* | 18.5 | 78* | ||||||
100 | 10 | 31.5* | 25 | 78* | ||||||
150-200 | 31.5 | 45* | 80 | 112.5 | ||||||
300-500 | 45 | 63* | 112.5 | 150* | ||||||
600 | 20/30 | 63 | 80* | 130 | 160* | |||||
800 | ||||||||||
1000 | 30 | 80 | 100* | 160 | 180* | |||||
1200 | ||||||||||
1500 | 30 | 40 | 30 | 20 | 100 | 120* | 160 | 200* | ||
2000-2500 | 60 | 30 | ||||||||
3000-3150 |
25 MHz benchtop oscilloscope
Key indicators
- 25MHz oscilloscope
- Dual analog channel and one external trigger channel
- Real-time sampling rate of 500MSa/s, equivalent sampling rate of 10GSa/s
- 7" color TFT-LCD display, 8 x 18 grid display range
- Rich triggering functions: edge, pulse, video, slope, alternation
- 3 cursor measurement, 32 parameters automatic measurement function
- 5 kinds of mathematical operation functions, FFT operation split screen display function
- Unique digital filtering function: low pass, high pass, band pass, band stop
- Ultra-thin design, compact size, easy to carry
product description
The METRIX®DOX2000 Series oscilloscopes are extremely compact and easy to use, and are specifically designed for laboratory use. The device is equipped with a full screen mode that can display 18 div. This allows the user to customize the display: select normal or continuous display, YT or XY format, adjust color, size, brightness, contrast, and more. The spin button and backlight button add a lot to the front panel. The oscilloscope is equipped with a handle that makes it easy to carry; the non-slip four feet make the device more stable for outdoor use. High performance and multiple functions for data acquisition and analysis. Storage depth 32 k or 2 M optimized analysis. Vertical sensitivity ranges from 2mV/div to 10 V/div. Horizontal sensitivity is 2.5 ns to 50 s/div. Advanced features: simple math functions (+ / - / x / ÷) and "real-time" FFT with synchronized waveforms. EASYSCOPE software is included to make it easier to manage your data and graphics.
Applications
- Embedded electronic circuit design and debugging
- Industrial control, power measurement
- Investigate transient signals
- Manufacturing test, electrical function test
- Higher education and research
- Maintenance service
3 Wire (Analogue) Earth Resistance Tester 1105 ER
FEATURES | |||||||||||||||||||||
● Capable of measuring earth resistance and earth voltage. ● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test. ● In addition to facilitating for precision measurement, test leads for simplified two-wire measuring system also are supplied as standard accessories. ● Battery operated. ● Battery life indicator. ● Calibration performed with supplied test leads. |
|||||||||||||||||||||
SPECIFICATIONS | |||||||||||||||||||||
|
3 Wire (Analogue) Earth Resistance Tester 1805 ER
FEATURES | |||||||||||||||||||||
● High quality Taut Band movement. ● Capable of measuring earth resistance and earth voltage. ● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test. ● Test test leads are supplied as standard accessories for simplified two-wire measuring system. ● Battery operated. ● Battery check function. ● Calibration performed with supplied test leads. |
|||||||||||||||||||||
SPECIFICATIONS | |||||||||||||||||||||
|
3 Wire (Analogue) Earth Resistance Tester 2105 ER
FEATURES | |||||||||||||||||||||
● Capable of measuring earth resistance and earth voltage. ● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test. ● In addition to facilitating for precision measurement, test leads for simplified two-wire measuring system also are supplied as standard accessories. ● Battery operated. ● Battery life indicator. ● Calibration performed with supplied test leads. |
|||||||||||||||||||||
SPECIFICATIONS | |||||||||||||||||||||
|
3 Wire (Analogue) Earth Resistance Tester 2705 ER
FEATURES | |||||||||||||||||||||
● High quality Taut Band movement. ● Capable of measuring earth resistance and earth voltage. ● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test. ● The test leads are supplied as standard accessories for simplified two-wire measuring system. ● Battery operated. ● Battery check function. ● Calibration performed with supplied test leads. |
|||||||||||||||||||||
SPECIFICATIONS | |||||||||||||||||||||
|
3 Wire (Analogue) Earth Resistance Tester 4105 ER
FEATURES | |||||||||||||||||||||
● Capable of measuring earth resistance and earth voltage. ● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test. ● In addition to facilitating for precision measurement, test leads for simplified two-wire measuring system also are supplied as standard accessories. ● Battery operated. ● Battery life indicator. ● Calibration performed with supplied test leads. |
|||||||||||||||||||||
SPECIFICATIONS | |||||||||||||||||||||
|
3 Wire (Analogue) Earth Resistance Tester ST-1505
FEATURES | |||||||||||||||||||||
● High quality Taut Band movement. ● Capable of measuring earth resistance and earth voltage. ● The timer operates automatically for about three to five minutes when the “PUSH BUTTON SWITCH” and “TIMER ON BUTTON” are pressed together. ● This will keep test “ON” for the duration of the timer. ● Battery check function. ● Calibration performed with supplied test leads. |
|||||||||||||||||||||
SPECIFICATIONS | |||||||||||||||||||||
|
3 Wire (Digital) Earth Resistance Tester 1620 ER
FEATURES | |||||||||||||||||||||
● Microprocessor-controlled. ● Measures earth resistance in three ranges : 40Ω, 400Ω, 4kΩ. ● Capable of measuring earth voltage. ● 3 ¾ digit (4000 counts). ● LCD backlight display. ● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test. ● Data hold function. ● Relative function. ● Auto power-off function. ● Low battery indication. ● Calibration performed with supplied test leads. |
|||||||||||||||||||||
SPECIFICATIONS | |||||||||||||||||||||
|
3 Wire (Digital) Earth Resistance Tester ST-1520
FEATURES | |||||||||||||||||||||||||||||
● Capable of measuring earth resistance and earth voltage. ● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test. ● Auto power off function. ● The timer operates automatically for about three to five minutes when the "PUSH BUTTON SWITCH" and "TIMER ON BUTTON" are pressed together. This will keep test "ON" for the duration of the timer. ● Timer for test function (count 3-5 minutes). ● Battery operated. ● Data hold function. ● Small and light weight. ● Calibration performed with supplied test leads. |
|||||||||||||||||||||||||||||
SPECIFICATIONS | |||||||||||||||||||||||||||||
|
3D gyratory rockers - SSM3, SSL3
3D gyratory rockers - SSM3, SSL3
Digital speed control and built-in timer
Optional tier system available to increase capacity
Both models provide a 3D gyratory motion, ideal for low foaming agitation, DNA extractions, staining and de-staining procedures etc. The angle of tilt can be moved to any position by hand to optimize mixing of vessels. Digital selection of both speed and time facilitates accurate and reproducible conditions. Both parameters are controlled via an easy to use encoder control knob and displayed on the bright LED display.
Both models are supplied with a non-slip mat which holds flat based vessels securely in place during mixing. An accessory tier system can be fitted in seconds, without the need for tools, tripling the available space for samples. Each tier is securely held in place by magnets.
SSM3 | SSL3 | |
---|---|---|
Rocking action | 3D gyratory | 3D gyratory |
Platform dimensions (w x l) | 235 x 235mm | 355 x 355mm |
Speed range | 5 to 70rpm | 5 to 70rpm |
Angle of tilt | 3 to 12° | 3 to 12° |
Angle adjustable | Yes by hand | Yes by hand |
Maximum load | 3kg | 10kg |
Overall dimensions (w x d x h) | 240 x 300 x 150 | 360 x 420 x 170 |
Tier height, mm | 125/tier | 125/tier |
Operational temp. range | +4 to +40°C | +4 to +40°C |
Max. permissible humidity | 80% | 80% |
Net weight | 5kg | 10kg |
Electrical supply | 230V, 50Hz, 50W | 230V, 50Hz, 50W |
Model | Description |
---|---|
SSM3 | Rocker, see-saw, mini |
SSL3 | Rocker, gyratory, lab scale |
SSM3/1 | Tier system (2 platforms plus 8 bars) fits SSM3 |
SSL3/1 | SSL3/1 Tier system (2 platforms plus 8 bars) fits SSL3 |
4 Wire Earth Resistance & Resistivity Tester 4235 ER
FEATURES | ||||||||||||||||||||||||||
● Microprocessor-controlled. ● Earth resistivity (ρ) test. ● Earth testing at 20Ω, 200Ω, 2kΩ. ● Earth voltage measuring : 0-300V AC. ● Automatic C spike check. ● Automatic P spike check. ● 2-Wire test, 3-Wire test, 4-Wire test. ● LCM display. ● Auto ranging. ● Auto power OFF. ● Data hold. ● 200 measurement results can be saved in the memory and recalled on the display. ● Interval between auxiliary earth spikes is 1.0~50.0m. |
||||||||||||||||||||||||||
SPECIFICATIONS | ||||||||||||||||||||||||||
|
4 Wire Earth Resistance & Resistivity Tester 4236 ER
FEATURES | |||||||||||||||||||||||
● Microprocessor-controlled. ● Earth resistivity (ρ) test. ● Earth testing at 20Ω, 200Ω, 2kΩ. ● Earth voltage measuring : 0-300V AC. ● Automatic C spike check. ● Automatic P spike check. ● 2-Wire test, 3-Wire test, 4-Wire test. ● LCM display. ● Auto ranging. ● Auto power OFF. ● Data hold. ● 200 measurement results can be saved in the memory and recalled on the display. ● Interval between auxiliary earth spikes is 1.0~50.0m. ● Optical USB to RS-232 data transmission. ● The stored data can be transferred to a PC. ● 2 optical LEDs are built-in for data transfer. |
|||||||||||||||||||||||
SPECIFICATIONS | |||||||||||||||||||||||
|
4 Wire Earth Resistance Testers 2734 ER
|
4 Wire Earth Resistance Testers 4234 ER
FEATURES | |||||||||||||||||||||
● Microprocessor-controlled. ● Earth testing at 2Ω, 20Ω, 200Ω, 2kΩ. ● Earth voltage measuring : 0-300V AC. ● Automatic C spike check. ● Automatic P spike check. ● 2-Wire test. ● 3-Wire test. ● 4-Wire test. ● LCM display. ● Auto ranging. ● Auto power OFF. ● Data hold. ● Robust, compact and easy-to-carry. |
|||||||||||||||||||||
SPECIFICATIONS | |||||||||||||||||||||
|
40 MHz handheld oscilloscope
Key indicators
- 20 or 40 MHz oscilloscope
- Double 8,000 count multimeter
- Harmonic analysis
- Power analysis
- LED backlight 3.5 inch 320x240 resolution color LCD TFT screen
- Isolated USB interface capable of communicating with the SCPI protocol
- SX-METRO Software
- View the graph on the storage file
- Display real-time graphs on a PC
- Control the scope with a PC
- Output data and graphs in Excel format
product description
- Power Analysis Ergonomics: - LED Backlight 3.5" 320x240 Resolution Color LCD TFT Screen - Easy to use, one button is equivalent to one function (trigger, configuration, etc.) - Integrated multi-language interactive help - can communicate with SCPI protocol Isolated USB interface communication and software: The HANDSCOPE oscilloscope can be connected to a PC via a separate fiber optic USB. The standard configuration of SX-Metro data processing software can be used to view the graph on the storage file - display the real-time graph on the PC - control the oscilloscope via PC - store the graph in text format on the PC - output data in Execl format and Graph
Applications
- Factory internal maintenance and repair
- Installation and operation monitoring
- Industrial process testing
- QC
- For R&D and laboratories - engineers or technicians
4CH Digital oscilloscope DSO4004B Series
DSO4004B Series
4CH oscilloscope, 80-250MHz bandwidth, minimum measurement range 500μV /div,1GS/s sample rate,advanced digital trigger system, high trigger sensitivity, low trigger jitter,high resolution 7 inch 64K color TFT (800*480)
Feature:
- 4CH oscilloscope+EXT+DVM+auto range function
- 80-250MHz bandwidth,minimum range 500μV /div,1GS/s sample rate.
- Over 32 types of auto measurement function
- Advanced digital trigger system, high trigger sensitivity.
- Over 14 types of trigger function: edge, overtime, pulse, pattern, interval, etc.
- Serial bus triggering and decode, Bus protocol information can be quickly and intuitively displayed in table form.
- Integrated USB Host/Device, convenient to communicate with PC. Support U-stick storage/systerm update.
- Support a variety of SCPI remote control command
- Support optional RS232 port, LAN port. (Optional)
- Stable and reliable quality, sturdy and durable.
4CH Digital oscilloscope DSO4004C Series
DSO4004C Series
4CH oscilloscope, with 1CH Arbitary/function waveform generator, independent keys of oscilloscope and waveform generator which is easy to operate at the same time.. 80-250MHz bandwidth, minimum measurement range 500μV /div,1GS/s sample rate,advanced digital trigger system, high trigger sensitivity, low trigger jitter,high resolution 7 inch 64K color TFT (800*480)
Feature:
- 4CH oscilloscope+EXT+AFG+DVM+auto range function
- 80-250MHz bandwidth,minimum range 500μV /div,1GS/s sample rate.
- Over 32 types of auto measurement function
- Advanced digital trigger system, high trigger sensitivity.
- Over 14 types of trigger function: edge, overtime, pulse, pattern, interval, etc.
- Serial bus triggering and decode, Bus protocol information can be quickly and intuitively displayed in table form.
- Function/arbitrary signal generator25MHz,12BitS resolution, 200MHz DDS, ARB/square wave/sine wave/triangular wave/trapezoidal wave/impulse wave/DC etc.,easy to simulate the sensor.
- Integrated USB Host/Device, convenient to communicate with PC. Support U-stick storage/systerm update.
- Support a variety of SCPI remote control command
- Support optional RS232 port, LAN port. (Optional)
- Stable and reliable quality, sturdy and durable.
60 MHz handheld oscilloscope
Key indicators
- 2 independent channels, 4000-point, TRMS, 200kHz digital multimeter function
- Color LCD touch screen oversized 320 x 240
- 2GB removable SD memory card
- Isolated USB interface capable of communicating with the SCPI protocol
- Multiple communication interfaces: RS-232, Ethernet (built-in WEB server)
- Smart probe with user-defined control buttons
- SX-METRO Software
- View the graph on the storage file
- Display real-time graphs on a PC
- Control the scope with a PC
- Output data and graphs in Excel format
product description
The oscilloscope OX 7062 is the ideal tool for laboratory testing and field testing.
The instrument is easy to operate and has direct access to all commonly used functions via 33 buttons. The OX 7062 is especially suitable for field use and is equipped with the latest patented “Plug and Play” probes. Each measurement channel is isolated and isolated from each other. It can be remotely controlled via a built-in WEB server and Ethernet. It's all in one, including a 2-channel TRMS multimeter.
Large 320 x 240 full color LCD display with detailed waveform detail and display of all measurements and functions. With the stylus, you can easily and quickly access the window menu: open, pull down or execute; the stylus can also directly act on graphical elements such as cursors, triggers and zooms.
Applications
- On-site repair - industrial or electronic
- Factory internal maintenance and repair
- Installation and operation monitoring
- Industrial process testing
- QC
- For R&D and laboratories - engineers or technicians
65-Gallon Wheeled Poly-Overpack Salvage Drum(Universal)
SYSBEL 65-Gallon Wheeled Poly-Overpack Salvage Drums are special containers which are suitable for temporary storage and transport of hazardous waste. Widely used in secondary packaging, transportation, emergency spill treatment to eliminate hazardous materials and secondary leakage occurs. Built-in wheels eliminate the need for a separate dolly or other transport; Help to provide you with the most effective and low cost safety solutions
70 MHz benchtop oscilloscope
Key indicators
- 70MHz oscilloscope
- Dual analog channel and one external trigger channel
- Real-time sampling rate 1GSa/s, equivalent sampling rate 50GSa/s
- 87" color TFT-LCD display, 8 x 18 grid display range
- Rich triggering functions: edge, pulse, video, slope, alternation
- 3 cursor measurement, 32 parameters automatic measurement function
- 5 kinds of mathematical operation functions, FFT operation split screen display function
- Unique digital filtering function: low pass, high pass, band pass, band stop
- Ultra-thin design, compact size, easy to carry
Applications
- Embedded electronic circuit design and debugging
- Industrial control, power measurement
- Investigate transient signals
- Manufacturing test, electrical function test
- Higher education and research
- Maintenance service
Acela™ Fume Hoods
Introducing Esco Frontier® Acela™ the world class laboratory fume hood design platform with patents and compliance to prove it. Precisely tuned aerodynamics, outstanding user safety, total systems and design flexibility, energy-efficiency, aesthetics and ergonomics- all supported by Esco's solutions-based sales and service representatives in more than 100 countries.
Key Benefits:
- ASHRAE 110 certified/ EN14175 certified
- UL Classified
- Excellent aesthetics
- 5 degree sloped front
- Unique perforated baffle design
- Superior containment at 0.3m/s
- High energy savings
- Unique Hot Zone Baffles capture fumes quickly.
- The tapered fibreglass exhaust collar reduces airflow turbulence, static pressure loss, noise level and increases face velocity uniformity.
- Perfect Pitch Profile™. The gentle pitch of the hood profile enhances visibility.
- Tri-wall construction and chain-and-sprocket sash system for maximum durability.
- Sash stop limits sash movement beyond 457 mm (18"). When raised above this height, sash will automatically and gently fall back to the safe level (Esco’s CreepDown Mechanism).
- Sash keylock available to keep sash in place at full open position for equipment loading, or at full close position to restrict access into hood.
- Constant volume / high performance concept eliminates the need for complex VAV systems.
- The Frontier® Acela™ Fume Hood delivers outstanding containment (less than 0.05ppm, as manufactured) down to 60fpm face velocity at both 18" restricted and full open sash openings, tested inhouse in accordance to the ASHRAE-110 and EN14175-3 test protocols.
- Independently certified by Tintschl Engineering, Germany, to comply with the requirements of the EN14175 fume hood test standard.
- All Frontier® Acela™ Fume Hoods include 1 water and 1 gas Enhanz™ remote-controlled fixture plumbed to the top of the hood and 2 duplex outlets standard (specify outlet code when ordering).
Acid Digestion™ fume hood
Acid Digestion™ is designed to handle very concentrated acids at high temperatures. This specialized fume hood is built with unplasticised polyvinylchloride (u-PVC) known for its superior chemical resistance while the sash window is made of polycarbonate to prevent etching.
Key Benefits:
- ASHRAE 110 and EN 14175 compliance assures maximum operator safety.
- Full uPVC or PP interior for excellent chemical resistance and avoid immediate corrosion.
- 5° angled front of the sash reduces glare and reflection for operator comfort.
- Superior containment at 0.3 m/s results to high energy savings.
- Tri-wall construction and chain-and-sprocket sash system for maximum robustness
- u-PVC exhaust collar ensures chemical resistance
- Polycarbonate sash to prevent etching
- Esco’s Creep down Mechanism: When sash is raised above 457 mm (18"), sash will automatically and gently fall back to the safe level.
- Baffle system rapidly draws contaminant out of the fume hood and thermal heat relief is achieved.
- Service fixtures include: 1 x water fixture, 1 x gas fixture, 4 single electrical outlets with splash proof cover and 1 PP drip cup.
- All Frontier Acela™ Fume Hoods include 1 water and 1 gas Enhanz™ remote-controlled fixture plumbed to the top of the hood and 2 duplex outlets standard. (Specify outlet code when ordering)
- Base Cabinet (EBA)
- Optional Hood circuit protection (EBA-8)
- Optional Hood circuit protection (EBA-8)
- Ventilation Kit (VK-EBA)
- Ventilates base cabinet utilizing the hood exhaust system.
- Field-installed.
- Filler Panel (FP-EBAD)
- One set of filler panels required per continuous row of hoods.
- Field-installed
- Special Flammable and Corrosive storage cabinets (ESF-F/C
advance EDI pure water systems
The arium® advance EDI consistently delivers Type 2 water of the best quality at rates of up to 10 l/h. This system makes the best use of your valuable water resources by automatically optimizing water usage with its intelligent I-Just software. Moreover, the arium® advance EDI attains the highest retention rates of ions, while providing an optimum yield of purified water. As a result, the arium® advance EDI reliably removes oxidants, heavy metal ions and particulates from feed water.
Unlike conventional water purification systems, this arium® system is designed with you and your busy-day schedule in mind: its unique, touch-function display, along with intuitive menu navigation, takes out the guesswork and puts in total ease of operation.
Pure water produced by arium® advance EDI is stored in the unique, closed arium® bagtank system, which reliably protects your purified water from secondary contamination. This ensures that you obtain the best water quality and, therefore, reproducible results.
Standard Applications:
- Pure water for preparation of microbiological media and reagents
- Pure water for preparation of solutions for chemical analysis and synthesis
- Histology
- ELISA, RIA
- Pure water for preparation of buffers and pH solutions
- Purification of feed water for laboratory instruments, such as autoclaves, glassware dishwashers, humidifiers, water baths, etc.
iJust
Compared with conventional water systems, the arium advance EDI with its iJust software makes the best use of your initial feed water conditions and water resources. Intelligent iJust enhances the quality of purified water, reduces water usage and calculates the optimal cleaning cycles for the system.
Display with Touch Function
Navigate easily and intuitively using the clearly structured arium® menu – a light touch on the display is all it takes for error-free control, even while you’re wearing gloves.
Major Advantages of arium® advance EDI:
The arium® integrates perfectly into your given space requirements in the lab, whether as a bench-top, wall-mounted or a built-in unit.
- The highest Type 2 water quality at all times
- Optimized, lean and green water usage
- Guaranteed longer life of downstream ultrapure water systems
- Total ease of use
- High system flexibility to meet your specific needs
Afterburner Ashing Furnace ABF
The ABF Afterburner Ashing Furnace is particularly suitable for ashing larger samples or materials such as biomass, which are likely to generate substantial amounts of smoke.
The furnace comprises a large main combustion chamber equipped as standard with a two tier set of sample baskets. The exhaust from the main chamber is processed through a high temperature afterburner designed to further process fumes and smoke.
Standard features
- 800°C maximum operating temperature - ashing chamber
- 28 Litre chamber volume
- Afterburner rated for up to 40 g carbon per ashing load
- Two tier baskets with loading tray and handle
- 3216P1 programmable controller
- Independent control of afterburner temperature up to 950°C
- Silicon carbide shielded wire wound elements
- Supplied with 3-phase supply as standard
Options (specify these at time of order)
- Over-temperature protection (recommended to protect valuable contents & for unattended operation)
- A range of sophisticated digital controllers, multi-segment programmers and data loggers is available. These can be fitted with RS232, RS485 or Ethernet communications
- Optional floor stand
Technical details
Airflow in the ABF 8/28 Ashing Furnace
- Air inlet – air is preheated before entering the chamber
- Air inlet into afterburner to ensure complete combustion
- Air inlet into plenum to cool the gases before entering the extraction fan
- Chimney
- Furnace chamber
- Afterburner
- Extraction fan
- Two tier perforated basket system
Content may be subject to modifications or corrections
Aggrameter
Aggrameter
The Aggrameter utilizes the latest microwave and microprocessor technology to measure moisture content in various fine and coarse-grained materials. The prongs of the probe are inserted into the material to be tested and the percentage of moisture content is instantaneously shown on the easy to read display. The Aggrameter comes calibrated for both sand and aggregate, and can be programmed by the user for up to ten different materials. The Aggrameter can store more than 150 readings – complete with time and date for future reference.
Air pycnometer according to Langer Product code: 08.60
Applications
The pycnometer is applied where there is an interest in knowing the specific weight.
- Soil research, for instance the determination of the porosity of soil samples. It is recommended to use soil sampling rings with a 100 cc contents when taking undisturbed soil samples.
- Powder- and granulate research in the pharmaceutical industry.
- Measuring the pore volume of tarmac (road construction) or clay and bricks (brickworks).
- Volume determinations of seeds, coffee beans, legumes, etc. in the food industry.
Limitation: Temperature variations influence the measurements (can be prevented by climate control in the laboratory).
ALL AMERICAN MODEL #75X
ALL AMERICAN MODEL #75X | ||||||||||||||||||||||||||||||||||||||||
41 QUART ELECTRIC STERILIZER | ||||||||||||||||||||||||||||||||||||||||
Wisconsin Aluminum Foundry was first in the field to develop an immersion-type pressure sterilizer for physicians’ offices, hospitals and laboratories. The electric ALL-AMERICAN® Sterilizer is a complete, self-contained unit with an immersion heating element, automatic thermostatic control, automatic release valve, and pilot light. It connects to any outlet, is ready for use instantly, and ensures complete, efficient sterilization.
|
||||||||||||||||||||||||||||||||||||||||
FEATURES | ||||||||||||||||||||||||||||||||||||||||
• 64% greater capacity compared to 25X |
Alligator 200 diaphragm liquid pump
Features :
◆ No air pollution, maintenance free
Alligator 200 diaphragm liquid pump is driven by diaphragm, without the need of lubricant, regular oil changes and maintenance; with no oil pollution.
◆ Save time & 40% bench space
Alligator 200 diaphragm liquid pump has a built-in liquid pump transferring filtered liquid directly to waste. No need of waste bottle.
International certification :
◆ CE certification
◆ IP 64 protection class
◆ RoHS certification
Applications :
◆ Microbiological test by MF Technique
◆ Suspended solid test for water monitoring
◆ General filtration without need of collecting filtrate
Ordering Information :
◆ 181200-01(02)
Alligator 200, Diaphragm Liquid Pump
with US Plug (EU Plug)
Alpha Bottle Only - 8.2L Vertical, Acrylic
Alpha Bottle Only - 8.2L Vertical, Acrylic
- Blue seals of durable, flexible, high-grade polyurethane resin
- 316 SS trip head for durability
- Not suitable for trace metal sampling
- Alpha Bottle Only
The following items are required for operation (NOT INCLUDED):
- messenger (3-45-B10)
- 100 ft. line (3-62-C15)
(See kits for all inclusive package)
Use vertical bottles in mildly corrosive water, marine water and water with large amounts of suspended solids or adhesive colloidal solids to collect plankton and floating sediments. The wide mouth collects a true water sample with no contamination from other water levels. During descent, the open mouth does not restrict water flow. This makes them particularly suitable for collecting plankton, floating sediments and for use where metallic ion avoidance is desirable. Your choice of transparent acrylic or more durable opaque PVC.
Alpha samplers are not suitable for trace metal analysis due to the potential for contamination (i.e. mercury and phosphorus) by the materials in the sampler’s end seals. For trace metal analysis, choose our Beta Bottle water samplers.
A thermometer can be mounted inside acrylic Alpha™ bottles.
NOTE: Volume may vary slightly. It is recommended that you verify the exact volume of your bottle prior to use.
Part # 3-1180-C45
Analitical Balance 120 gr
Reduce Your risk with integrated and intelligent protection systems
Secura® gives you the security and peace of mind of knowing that you have done everything right. Besides providing highly accurate weighing results and operating convenience, Secura® also features built-in protection systems for complete reliability and regulatory compliance – the safe and secure way.
Real-time guidance prompts for leveling, automatic internal adjustment, and 100% traceable, clear documentation with sample and batch identifiers make your lab work more efficient.
- Integrated protection systems for minimizing your risk of obtaining incorrect results
- Real-time alarm messaging and interactive user guidance for leveling to prevent inaccurate results due to an unleveled balance
- SQmin for automatic detection and active monitoring to ensure you are within the acceptable USP operating range for reliable results
- Fully automatic internal adjustment function, isoCAL, for the highest possible accuracy at all times
- Cal Audit Trail for easy, traceable documentation of all calibration and adjustment data
- Safe and clear documentation by sample and batch identifiers for keeping perfect track of weighing data
- GLP-|GMP-compliant printouts
- Standard password security features for protection against tampering and unauthorized access
- Integrated PC direct function and Plug & Work connectivity to a Sartorius printer
What's included:
Universal power adapter, in-use cover, Application Guide, dust cover for analytical balances and a draft shield ring for 0.1 mg balances.
Analitical Balance 60 Gr
Redefining Standard
Quintix® makes laboratory work more enjoyable. The intuitive touch-screen in combination with the most precise weighing technology make Quintix® laboratory balances the only choice to achieve the best results. You will benefit from improved workflows by easy-to-use application programs. If you need to generate GLP-compliant documents, you will save considerable time and effort with the “plug and work” connectivity of Quintix® laboratory balances.
- Intuitive operation of the balance without having to read a manual thanks to the new user interface and color touch screen
- Integrated application programs and intuitive user guidance for greater efficiency in your daily lab routine
- Highest accuracy and convenience ensured at all times by the isoCAL fully automatic internal adjustment feature
- Easier record-keeping using the balance's directly integrated PC functions and Plug & Work connectivity to a Sartorius lab printer
What's included:
Universal power adapter, in-use cover, application guide, dust cover for analytical balances
Analitical Balance 80,160,320 g
Users can choose from thousands of options to configure their balance to suit their individual needs and obtain the optimal solution for integration into their process. But we didn’t stop at this level of innovation: when customers require a perfect solution to allow them to incorporate the lab balance into their processes in a fully individual way, configurability is simply not enough. We provide an elegant software solution that needs no additional laptop to implement a fully individual profile of specifications – from the integration of data into the infrastructure of the software to the complete control of the weighing process – and beyond. Your benefits: quick, clearly defined processes and accuracy. But the growth on the 'hardware side' of the Cubis® family is unstoppable as well. With the new high capacity models, Cubis® now covers the entire range from the research and QC laboratory to the process development labs and compounding areas. Here, Cubis® offers you the comprehensive accessories program to fit the solutions for your fully individual applications as well.
Cubis®. Buffet, à la Carte or Fully Customized?
Universal lab balances often have only limited options for adaptation to special workflows in laboratories. Usually, a situation results where SOPs have to be modified to work around the balance functionalities available.
Sartorius Cubis® balances overcome these limitations. They are the first laboratory balances that not only can be seamlessly integrated into your individual workflows. Thanks to a wide selection of accessories and mechanical components for extended options, these balances can also be adapted to your weighing containers and workplace conditions better than any other balance.
Users can choose from thousands of options to configure their balance to suit their individual needs and obtain the optimal solution for integration into their process. But we didn’t stop at this level of innovation: When customers require a perfect solution to allow them to incorporate the lab balance into their processes in a fully individual way, configurability is simply not enough. With , we provide an elegant software solution that needs no additional laptop to implement a fully individual profile of specifications – from the integration of data into the infrastructure of the software to the complete control of the weighing process – and beyond. Your benefits: quick, clearly defined processes and accuracy. But the growth on the 'hardware side' of the Cubis® family is unstoppable as well. With the new high capacity models, Cubis® now covers the entire range from the research and QC laboratory to the process development labs and compounding areas. Here, Cubis® offers you the comprehensive accessories program to fit the solutions for your fully individual applications as well.
Safe and Easy to Use with Standard Q-Guide
In addition to aspects strictly involving metrological specifications, preparing for and performing a weighing procedure and meeting the relevant regulatory standards are gaining ever-increasing importance. With the Q-Guide user interface, work tasks are not only faster but Q-Guide eliminates the need for the user to follow time-consuming working steps. The Q-Guide is designed so that the user only ever sees what is needed for carrying out the task at hand. Once a task has been defined, Q-guide guides the user interactively through the settings and hides information that is not relevant.
Individuality is the Key - More Efficiency and Safety with Q-Apps
Turn your Cubis® lab balance into Cubis®individual, and integrate customer-specific applications, called Q-Apps, into your balance. These are reloadable application programs that guide the user step-by-step through the specific workflow. It is thus guaranteed that the procedures described in the corresponding SOPs are observed at all times. This makes Q-Apps an attractive alternative to implementing external middleware.
Choose between Two Types of Q-Apps
As individual Q-Apps are performed according to their specific application, a variety of solutions for differential weighing, formula and filling quantity control applications are available as standard Q-Apps. Moreover, it is also possible to use standardized Q-Apps applications for the determination of the minimum sample weight according to USP as well as for easy pipette calibration. Workflows can be performed independently and do not necessarily require a PC connection.
Q-Level - The Automatic, Motorized Leveling Function
Exact leveling of a lab balance is the key element in inspection equipment monitoring and is essential for reliable readings. This is where Q-Level can provide valuable support, because users can define which tasks they will perform themselves and which the balance should carry out on its own. This is possible regardless of which of the three display | control units is chosen. Cubis® is the first lab balance that automatically checks, performs and documents its exact leveling. The Cubis® balance can be leveled with the push of a button or fully automatically when the isoCALfunction has been activated. Quick and safe leveling with a significantly reduced risk of contamination for users when they work with toxic substances in safety weighing cabinets. This eases the burden on the user and allows more time for the user’s actual tasks, in addition to being safer.
Analogue (1kV below) Insulation Tester 1180 IN
FEATURES |
● High quality Taut Band movement. |
Analogue ELCB Tester
FEATURES |
● Taut Band movement.
● Simple operation. ● Wiring check. ● Robust. ● Can be used on 2 wires L-E (ELCB/RCCB/GFCI tester). ● Can be used on 3 wires L-E-N (with wiring check). ● No battery required. ● Sense automatically 50 or 60 Hz. ● Current injected in phase with the voltage. ● Other voltage optional (110V). |
Analytical Balance 320 g x 0.1 mg
Reduce Your risk with integrated and intelligent protection systems
Secura® gives you the security and peace of mind of knowing that you have done everything right. Besides providing highly accurate weighing results and operating convenience, Secura® also features built-in protection systems for complete reliability and regulatory compliance – the safe and secure way.
Real-time guidance prompts for leveling, automatic internal adjustment, and 100% traceable, clear documentation with sample and batch identifiers make your lab work more efficient.
- Integrated protection systems for minimizing your risk of obtaining incorrect results
- Real-time alarm messaging and interactive user guidance for leveling to prevent inaccurate results due to an unleveled balance
- SQmin for automatic detection and active monitoring to ensure you are within the acceptable USP operating range for reliable results
- Fully automatic internal adjustment function, isoCAL, for the highest possible accuracy at all times
- Cal Audit Trail for easy, traceable documentation of all calibration and adjustment data
- Safe and clear documentation by sample and batch identifiers for keeping perfect track of weighing data
- GLP-|GMP-compliant printouts
- Standard password security features for protection against tampering and unauthorized access
- Integrated PC direct function and Plug & Work connectivity to a Sartorius printer
What's included:
Universal power adapter, in-use cover, Application Guide, dust cover for analytical balances and a draft shield ring for 0.1 mg balances.
Anatomy Chart: Anatomy And Injuries Of The Shoulder
Great for patient and student education, this laminated chart (20" x 26") highlights the normal anatomy of the shoulder as well as common shoulder injuries. Features detailed and labeled illustrations that show the anatomy of the shoulder and injuries of the shoulder, such as a rotator cuff tear, dislocation of the humerus, bicipital tendonitis, and more. Printed on heavy paper stock. Perfect for healthcare professionals’ offices
Anatomy Chart: Anatomy Of The Teeth
A great teaching tool for dentists to use with patients and students, this chart uses detailed drawings to explain the anatomy of the teeth. Ideal for dental education, the chart is printed on heavy card stock and laminated.
Anatomy Chart: The Female Reproductive
Detailed and accurate, this masterfully produced, laminated chart (20" x 26") highlights the female reproductive system. Labeled illustrations depict an unfertilized ovum; the ovary, fallopian tube, uterus, and vagina; the female pelvic organs; the female perineum; and ovulation. Also includes additional information about the menstrual cycle and menopause.
Anatomy Chart: The Male Reproductive System
Explaining the male reproductive system is simplified with this laminated chart (20" x 26"). Features detailed and labeled illustrations that show a sagittal section of the pelvic organ, anterior and posterior views of the system, a cross section of the penis, and more. Printed on heavy paper stock. Great for patient and student education.
Anatomy Chart: The Respiratory System
With accurate details and labeling, this laminated chart (20" x 26") illustrates the complete respiratory system from the frontal sinus to the diaphragm. The central illustration shows the lungs and conducting system, while the surrounding illustrations depict detailed views of the paranasal sinuses, larynx, and more. Printed on heavy paper stock. Great for patient and student education
Aquatron water still - A4000, A4000D, A8000
Aquatron water still - A4000, A4000D, A8000
High purity pyrogen free output
Low temperature distillate
Operates from any raw water supply
Reservoir level control
Simple conversion to pre-treated feed
Supplied with wall mounting bracket
Safety features allow unattended operation
Simple to clean
Three models are available giving outputs of 4 or 8 litres/hour single or 4 litres/hour double distilled water. The high quality borosilicate glassware coupled with silica sheathed heaters gives pyrogen free distillate of the highest purity from virtually any raw water supply.
The unique condenser design ensures that the droplets of distilled water remain in contact with the cooling coil for the longest possible time ensuring maximum energy transfer. This produces cold distilled water ready for immediate use and pre-heats the boiler feed to increase efficiency.
All glass construction allows rapid descaling using strong mineral acids. A built in "clean" function and integral acid addition funnel make the cleaning operation simple and safe with no need to dismantle any of the glassware. A large bore stopcock with PTFE key is fitted for easy draining of chemicals after cleaning.
A flow sensing device will detect any reduction in the flow of cooling water to below the required level and will turn off the still before it can overheat. Sensing the flow of cooling water rather than its pressure is safer and allows the still to run normally on low pressure supplies down to 3psi (20kPa). As a fail-safe device there is an over-temperature thermostat mounted in the boiling chamber.
The Aquatron is very easy and safe to assemble and maintain. Both the acrylic safety screen and the cabinet lid are removable giving unrivalled access to the glassware components. Screwthreads are incorporated on all water connections so hoses can be fitted and removed easily and safely without risk of breakage.
Every Aquatron® water still is supplied with a reservoir level control.
The control is a simple and effective system which can be fitted to virtually any type of reservoir vessel. It will turn the still off when the reservoir is full and restart it when the level in the reservoir drops as distilled water is removed for use making it fully automatic. water purification
A4000
Produces 4 litres/hour single distilled water. Can operate standing on the laboratory bench or be wall mounted. Supplied with easy to fit wall mounting bracket.
A8000
Produces 8 litres/hour single distilled water, ideal for the larger laboratory. Glassware is enclosed in the same cabinet as the A4000 so can operate standing on the laboratory bench or be wall mounted. Supplied with easy to fit wall mounting bracket.
A4000D
Produces 4 litres/hour double distilled water for higher purity levels. The first stage distillation is carried out in a glassware set mounted at the front of the cabinet allowing easy access for descaling. The distilled water is fed to a second set of glassware mounted at the rear and distilled a second time. The rear glassware is fitted with a level sensor to ensure the heater is only activated when there is sufficient water in the boiler.
A4000 | A8000 | A4000D | |
Output, lhr | 4, single | 8, single | 4, double |
pH | 5.0 - 6.5 | 5.0 - 6.5 | 5.0 - 6.5 |
Conductivity, µ Scm-1 | 1.0 - 2.0 | 1.0 - 2.0 | 1.0 - 1.5 |
Resistivity, mOhm-cm | 0.5 - 1.0 | 0.5 - 1.0 | 0.7 - 1.0 |
Temperature, °:C | 25 - 35 | 25 - 35 | 25 - 35 |
Pyrogen content* | Pyrogen free | Pyrogen free | Pyrogen free |
Water supply | 1 lmin, 3-100psi, (20-700kPa) | 2 lmin, 3-100psi, (20-700kPa) | 2 lmin, 3-100psi, (20-700kPa) |
Electrical supply | 220 or 240V, 50-60Hz, single phase | 220 or 240V, 50-60Hz, single phase | 220 or 240V, 50-60Hz, single phase |
Max. power, kW | 3 | 6 | 6 |
Dimensions (wxdxh), mm | 550x240x410 | 550x240x410 | 550x410x410 |
Model | Description |
---|---|
A4000 | Aquatron water still, 4 l/hr, single distilled, 240V |
A4000/220 | Aquatron water still, 4 l/hr, single distilled, 220V |
A8000 | Aquatron water still, 8 l/hr, single distilled, 240V |
A800/220 | Aquatron water still, 8 l/hr, single distilled, 220V |
A400D | Aquatron water still, 4 l/hr, double distilled, 240V |
A4000D/220 | Aquatron water still, 4 l/hr, double distilled, 220V |
Arbitrary waveform generator HDG2000B Series
HDG2000B Series
16Bit Resolution, 250MSa/s Sample Rate; 64M Memory Depth; 16 channels digital output, 7 inch, 64K true color TFT display, WVGA(800X480)
- 16Bit Resolution, 250MSa/s Sample Rate; 64M Memory Depth;
- 100/80/60/30MHz. Sine Output Frenquency;
- 16 channels digital output, together with the analog channel can rebuild the more mixed signals in daily practice
- Support AM, FM, PM, ASK, FSK, PSK and PWM modulations
- TCXO timebase standard, OCXO optional for ultra-high stability
- 7 inch, 64K true color TFT display, WVGA(800X480)
- Plenty of interfaces: USB Host, USB Device, LAN
- 80M Frequency Counter;
arbitrary waveform generator HDG6000B/HDG6000C
HDG6000B/HDG6000C
HDG6000B/HDG6000C series integrates multi-function like arbitrary waveform generator, pulse generator, 16-bit word generator, 7-digit cymometer and function generator; It can generate and output stable, accurate and low distortion signals; Built-in over 40 type arbitrary waveforms, which is easy to simulate various signals; Its large screen, user-friendly interface design and keyboard layout are convenient to use, the standard touch screen of HDG6000C series brings extraordinary experience to users; Rich standard configuration interfaces easily achieve remote control of the instrument.
Features:
HDG6000B/HDG6000C series integrates multi-function like arbitrary waveform generator, pulse generator, 16-bit word generator, 7-digit cymometer and function generator; It can generate and output stable, accurate and low distortion signals; Built-in over 150 type arbitrary waveforms, which is easy to simulate various signals; Its large screen, user-friendly interface design and keyboard layout are convenient to use, the standard touch screen of HDG6000C series brings extraordinary experience to users; Rich standard configuration interfaces easily achieve remote control of the instrument.
* Output frequency range: 1uHz ~ 200MHz / 160MHz / 110MHz / 80MHz;
* Up to 1.25GSa/s sampling rate, 16bits vertical resolution to ensure the accuracy of the output waveform;
* Up to 64M memory depth, ensuring better waveform detail creation;
* Large and clear display screen (7.0-inch LCD color display, resolution up to 800x640), user interface is clear and intuitive;
* A rich set of modulation functions, support AM, FM, PM, 2ASK, 2FSK, 2PSK and PWM etc. ;
* 1uHz frequency resolution; minimum 2mv output amplitude;
* Built-in 7-digit high-resolution 200MHz cymometer; with optional higher performance cymometer;
* Standard communication interface: HDG6000B series: USB Host, USB Device, optional RS232 interface;
* Standard communication interface: HDG6000C series: USB Host, USB Device, LAN port, Wi-Fi, touch screen, optional RS232 interface;
* Built-in more than 150 arbitrary waveforms, including exponential rise, exponential drop, ECG signal, Gaussian, semi-positive, Lorentz, dual-tone multi-frequency, DC voltage, etc.
Ash Fusibility Test Furnace - CAF G5 Coal & Coke Test Equipment
The CAF G5 is a furnace designed to test ash fusibility, and optionally, the increasingly popular determination of biomass or solid recovered fuels testing.
The coal ash fusibility test furnace conforms to the Standards ISO 540:2008; ASTM D 1857 / D1857M – 04 (2010); DIN 51730:2007-09; DD CEN/TS 15370-1:2006 (biomass) and PD CEN/TR 15404:2010 (solid recovered fuels (SRF)).
The CAF G5’s automatic and continuous recording of digital images allows laboratory technicians to carry out other tasks while the test is in progress, reviewing results later. The new CAF G5 greatly enhances the quality of the recorded images and test results increasing efficiency in laboratories.
The maximum temperature of 1600 °C enables both biomass and coal testing. An optional work tube integrated lighting system is also available when testing low ‘initial deformation’ temperature of SRF or biomass samples.
Standard features
- Analysis software which can be used in fully automatic or manual modes
- Software zoom function to enable accurate post-test analysis of individual samples with improved resolution
- One configurable grid assigned to each test piece
- Temperature controller program set up within the software
- Space saving embedded computer with Windows 7 Embedded Professional software runs future proof firmware
- Default software settings and individual analysis form for coal ash, biomass and SRF
- An optional work tube integrated lighting system when testing low initial deformation temperature of biomass or SRF samples
- Lightweight insulation allows quick cooling permitting multiple tests to be completed during the day
- Automated digital image capture of samples. The frequency of images recorded is set by customer preference, from every 1 °C increment to every 20 °C. The maximum interval for auto analysis is 5°C.
Technical details
View inside
- 1600 °C tube furnace with integral SiC elements
- External link to embedded PC & software
- Flow meters for oxidising, reducing gas flow (dependant on the requirements of the standards)
- 79 mm inner diameter work tube allows more than 6 samples
- Digital camera for fast and accurate image recording
- Gas tight seal for efficient use of gases & safety of operator
- Automatic temperature programmer with multiple PID control
- Gas inlets for reducing, oxidising & purge gasses
- Oxidising or reducing gas selection switch
- Work tube integrated light for use when testing low ‘initial deformation’ temperature of biomass and SRF samples (optional)
Content may be subject to modifications or corrections
Ashing Furnace AAF - 18 & 32 litres
The AAF ashing furnace range is designed specifically to provide optimum ashing conditions to ensure complete combustion of the sample.
For those laboratories where ashing is interspersed with other heat treatment work the ashing furnace AAF 12/18 & AAF 12/32 provide all of the advantages of the AAF design, but with a higher maximum operating temperature of 1200 °C.
Standard features
- 1100 °C & 1200 °C maximum operating temperatures
- Carbolite Gero 301 single ramp to setpoint & process timer
- Two tier rack system doubling the sample capacity
- With sample trays and loading handle allows for large number of samples
- Ideal for ashing foods, plastics, coal & other hydrocarbon materials
- Preheating of air before it enters the chamber
- Protection of the elements from carbon build-up or corrosive atmosphere, using silicon carbide tiles
- 2 sided heating
Options (specify these at time of order)
- A range of sophisticated digital controllers, multi-segment programmers and data loggers is available. These can be fitted with RS232, RS485 or Ethernet communications
- Over-temperature protection (recommended to protect valuable contents & for unattended operation)
Ashing Furnace AAF-BAL
The AAF-BAL thermogravimetric analysis (TGA) furnace incorporates an integral balance. It can be used for loss on ignition applications where weight change of the sample must be monitored during the heating process.
The AAF-BAL ashing furnace is fitted with an integral balance and can be used for loss on ignition (LOI) applications. Weight change of the sample is monitored during the heating process and this is required, for example, in the determination of organic matter content in materials such as sediment, sludge, soil and waste. Inorganic materials such as cement, lime, calcinated bauxite and refractories can also be tested.
Standard features
- Carbolite Gero 301 single ramp to setpoint & process timer
- Protection of the elements from carbon build-up or corrosive atmosphere, using silicon carbide tiles
- 2 sided heating
- Balance runs independently of the furnace control system
- Software supplied with the balance could be used to monitor the balance reading via a computer
- Maximum capacity of balance is 3 kg with a resolution of 0.01 g (other capacities available)
Options (specify these at time of order)
- Advanced version: The balance is linked to a 3508P1 temperature controller and both temperature and weight can be logged against time using iTools software
- A range of sophisticated digital controllers, multi-segment programmers and data loggers is available. These can be fitted with RS232, RS485 or Ethernet communications
- Over-temperature protection (recommended to protect valuable contents & for unattended operation)
- 8 kg balance with a resolution of 0.1 g