<table< p=""> </table<>
HR-2500 | |
---|---|
Horse power | 3.5 |
Motor: volts/amps | 115/20 |
Cycle | 50/60 |
Bit capacity | 12" |
Auger capacity | NA |
Column dimensions | 2.5" x 35" |
Carriage travel | 22" |
he dry type current transformers GFLZZ0954-10E are cast in epoxy resin insulated with big surface creepage distance and are excellent in anti-pollution and humidity protection. With high grade accuracy, it is suitable for protection against large short-circuit current, secondary current output 1A or 5A. The performances of the products meet standards IEC60044-1, IEC61869-2 and ANSI/IEEE C57.13.
Technical parameters | |
---|---|
Standards | IEC60044; IEC 61869; ANSI/IEEE C57.13 |
Rated primary current | 5-1250A |
Rated load | ≤15VA |
Rated frequency | 50Hz or 60Hz |
Rated secondary current | 5A or 1A |
Rated short-time thermal current | 140kA, 1S |
Rated dynamic current | 350KA |
Rated insulation level | 12/42/75KV |
FS | ≤10 |
Mechanical parameters | |
Material | Epoxy resin |
Weight (kg) | 32 |
Operating conditions | |
Operating temperature | -25°C to +55°C |
Daily average temp | <+40°C |
Storage temperature | -40°C to +70°C |
Altitude | <1000 meters |
Condition | No existence of severely begrimed, erosive and radioactive gas in the air. Permission of long-term operation under rated current. |
Ratied Primary Current(A) | Class Combination | Accuracy class and Rated output(VA) | Short-time thermal current(kA/S) | Rated dynamic current(kA) | |
---|---|---|---|---|---|
0.5 | 10P10 | ||||
5-150 |
0.2(S)/10P10 0.5/10P10 |
10 | 15 | 150 I1n | 375 I1n |
200 | 36 | 90 | |||
300 | 45 | 100 | |||
400-600 | 63 | 150 | |||
800-1000 | 100 | 250 | |||
1250 | 140 | 350 |
Key indicators
Applications
Key indicators
product description
100mA milliohm meter
Applications
Key indicators
product description
10A micro-ohmmeter, high precision, large range, suitable for various environments
Applications
170cm x 40cm x 30cm (66.93in x 15.75in x 11.81in)
Feature:
Key indicators
product description
The oscilloscope OX 7202 is the ideal tool for laboratory testing and field testing.
The instrument is easy to operate and has direct access to all commonly used functions via 33 buttons. The OX 7202 is especially suitable for field use and is equipped with the latest patented “Plug and Play” probes. Each measurement channel is isolated and isolated from each other. It can be remotely controlled via a built-in WEB server and Ethernet. It's all in one, including a 2-channel TRMS multimeter.
Large 320 x 240 full color LCD display with detailed waveform detail and display of all measurements and functions. With the stylus, you can easily and quickly access the window menu: open, pull down or execute; the stylus can also directly act on graphical elements such as cursors, triggers and zooms.
Applications
Key indicators
product description
The OX7204-BUS bus analysis oscilloscope can be used to perform on-site evaluation of bus technology integrity and to detect synchronization of bus electrical specifications. A series of communication lines consisting of fieldbus, electronic signals will be transmitted between two remote communication devices. Such a transmission system will replace the traditional 4-20 mA analog signal. At the site, various disturbances (deterioration of wiring, electromagnetic radiation, aging of insulators, leakage, etc.) may cause errors in signal transmission.
Applications
Technical parameters | |
---|---|
Standards | IEC60044; IEC 61869; ANSI/IEEE C57.13 |
Rated primary current | 5-3150A |
Rated load | ≤60VA |
Rated frequency | 50Hz or 60Hz |
Rated secondary current | 5A or 1A |
Rated short-time thermal current | 120kA, 1S |
Rated dynamic current | 200KA |
Rated insulation level | 12/42/75KV |
FS | ≤10 |
Mechanical parameters | |
Material | Epoxy resin |
Weight (kg) | 28 |
Operating conditions | |
Operating temperature | -25°C to +55°C |
Daily average temp | <+40°C |
Storage temperature | -40°C to +70°C |
Altitude | <1000 meters |
Condition | No existence of severely begrimed, erosive and radioactive gas in the air. Permission of long-term operation under rated current. |
Ratied Primary Current(A) | Class Combination | Accuracy class and Rated output(VA) | Short-time thermal current(kA/S) |
Rated dynamic current(kA)
|
||||||
---|---|---|---|---|---|---|---|---|---|---|
0.2(S) | 0.5(S) | 10P10 | 10P15 | 10P20 | ||||||
5 | 0.2(S)/0.5(S) 0.2(S)/10P 0.5(S)/10P |
10 | 20 | 20 | 20 | 15 | 0.5 | 1* | 1.25 | 2.5* |
10 | 1 | 2* | 2.5 | 5* | ||||||
15 | 1.5 | 3* | 3.75 | 7.5* | ||||||
20 | 2 | 4* | 5 | 10* | ||||||
30 | 3 | 6* | 7.5 | 15* | ||||||
40 | 4 | 8* | 10 | 20* | ||||||
50 | 5 | 20* | 12.5 | 50* | ||||||
75 | 7.5 | 31.5* | 18.5 | 78* | ||||||
100 | 10 | 31.5* | 25 | 78* | ||||||
150-200 | 31.5 | 45* | 80 | 112.5 | ||||||
300-500 | 45 | 63* | 112.5 | 150* | ||||||
600 | 20/30 | 63 | 80* | 130 | 160* | |||||
800 | ||||||||||
1000 | 30 | 80 | 100* | 160 | 180* | |||||
1200 | ||||||||||
1500 | 30 | 40 | 30 | 20 | 100 | 120* | 160 | 200* | ||
2000-2500 | 60 | 30 | ||||||||
3000-3150 |
Key indicators
product description
The METRIX®DOX2000 Series oscilloscopes are extremely compact and easy to use, and are specifically designed for laboratory use. The device is equipped with a full screen mode that can display 18 div. This allows the user to customize the display: select normal or continuous display, YT or XY format, adjust color, size, brightness, contrast, and more. The spin button and backlight button add a lot to the front panel. The oscilloscope is equipped with a handle that makes it easy to carry; the non-slip four feet make the device more stable for outdoor use. High performance and multiple functions for data acquisition and analysis. Storage depth 32 k or 2 M optimized analysis. Vertical sensitivity ranges from 2mV/div to 10 V/div. Horizontal sensitivity is 2.5 ns to 50 s/div. Advanced features: simple math functions (+ / - / x / ÷) and "real-time" FFT with synchronized waveforms. EASYSCOPE software is included to make it easier to manage your data and graphics.
Applications
FEATURES | |||||||||||||||||||||
● Capable of measuring earth resistance and earth voltage. ● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test. ● In addition to facilitating for precision measurement, test leads for simplified two-wire measuring system also are supplied as standard accessories. ● Battery operated. ● Battery life indicator. ● Calibration performed with supplied test leads. |
|||||||||||||||||||||
SPECIFICATIONS | |||||||||||||||||||||
|
FEATURES | |||||||||||||||||||||
● High quality Taut Band movement. ● Capable of measuring earth resistance and earth voltage. ● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test. ● Test test leads are supplied as standard accessories for simplified two-wire measuring system. ● Battery operated. ● Battery check function. ● Calibration performed with supplied test leads. |
|||||||||||||||||||||
SPECIFICATIONS | |||||||||||||||||||||
|
FEATURES | |||||||||||||||||||||
● Capable of measuring earth resistance and earth voltage. ● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test. ● In addition to facilitating for precision measurement, test leads for simplified two-wire measuring system also are supplied as standard accessories. ● Battery operated. ● Battery life indicator. ● Calibration performed with supplied test leads. |
|||||||||||||||||||||
SPECIFICATIONS | |||||||||||||||||||||
|
FEATURES | |||||||||||||||||||||
● High quality Taut Band movement. ● Capable of measuring earth resistance and earth voltage. ● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test. ● The test leads are supplied as standard accessories for simplified two-wire measuring system. ● Battery operated. ● Battery check function. ● Calibration performed with supplied test leads. |
|||||||||||||||||||||
SPECIFICATIONS | |||||||||||||||||||||
|
FEATURES | |||||||||||||||||||||
● Capable of measuring earth resistance and earth voltage. ● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test. ● In addition to facilitating for precision measurement, test leads for simplified two-wire measuring system also are supplied as standard accessories. ● Battery operated. ● Battery life indicator. ● Calibration performed with supplied test leads. |
|||||||||||||||||||||
SPECIFICATIONS | |||||||||||||||||||||
|
FEATURES | |||||||||||||||||||||
● High quality Taut Band movement. ● Capable of measuring earth resistance and earth voltage. ● The timer operates automatically for about three to five minutes when the “PUSH BUTTON SWITCH” and “TIMER ON BUTTON” are pressed together. ● This will keep test “ON” for the duration of the timer. ● Battery check function. ● Calibration performed with supplied test leads. |
|||||||||||||||||||||
SPECIFICATIONS | |||||||||||||||||||||
|
FEATURES | |||||||||||||||||||||
● Microprocessor-controlled. ● Measures earth resistance in three ranges : 40Ω, 400Ω, 4kΩ. ● Capable of measuring earth voltage. ● 3 ¾ digit (4000 counts). ● LCD backlight display. ● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test. ● Data hold function. ● Relative function. ● Auto power-off function. ● Low battery indication. ● Calibration performed with supplied test leads. |
|||||||||||||||||||||
SPECIFICATIONS | |||||||||||||||||||||
|
FEATURES | |||||||||||||||||||||||||||||
● Capable of measuring earth resistance and earth voltage. ● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test. ● Auto power off function. ● The timer operates automatically for about three to five minutes when the "PUSH BUTTON SWITCH" and "TIMER ON BUTTON" are pressed together. This will keep test "ON" for the duration of the timer. ● Timer for test function (count 3-5 minutes). ● Battery operated. ● Data hold function. ● Small and light weight. ● Calibration performed with supplied test leads. |
|||||||||||||||||||||||||||||
SPECIFICATIONS | |||||||||||||||||||||||||||||
|
FEATURES | ||||||||||||||||||||||||||
● Microprocessor-controlled. ● Earth resistivity (ρ) test. ● Earth testing at 20Ω, 200Ω, 2kΩ. ● Earth voltage measuring : 0-300V AC. ● Automatic C spike check. ● Automatic P spike check. ● 2-Wire test, 3-Wire test, 4-Wire test. ● LCM display. ● Auto ranging. ● Auto power OFF. ● Data hold. ● 200 measurement results can be saved in the memory and recalled on the display. ● Interval between auxiliary earth spikes is 1.0~50.0m. |
||||||||||||||||||||||||||
SPECIFICATIONS | ||||||||||||||||||||||||||
|
FEATURES | |||||||||||||||||||||||
● Microprocessor-controlled. ● Earth resistivity (ρ) test. ● Earth testing at 20Ω, 200Ω, 2kΩ. ● Earth voltage measuring : 0-300V AC. ● Automatic C spike check. ● Automatic P spike check. ● 2-Wire test, 3-Wire test, 4-Wire test. ● LCM display. ● Auto ranging. ● Auto power OFF. ● Data hold. ● 200 measurement results can be saved in the memory and recalled on the display. ● Interval between auxiliary earth spikes is 1.0~50.0m. ● Optical USB to RS-232 data transmission. ● The stored data can be transferred to a PC. ● 2 optical LEDs are built-in for data transfer. |
|||||||||||||||||||||||
SPECIFICATIONS | |||||||||||||||||||||||
|
|
FEATURES | |||||||||||||||||||||
● Microprocessor-controlled. ● Earth testing at 2Ω, 20Ω, 200Ω, 2kΩ. ● Earth voltage measuring : 0-300V AC. ● Automatic C spike check. ● Automatic P spike check. ● 2-Wire test. ● 3-Wire test. ● 4-Wire test. ● LCM display. ● Auto ranging. ● Auto power OFF. ● Data hold. ● Robust, compact and easy-to-carry. |
|||||||||||||||||||||
SPECIFICATIONS | |||||||||||||||||||||
|
Key indicators
product description
- Power Analysis Ergonomics: - LED Backlight 3.5" 320x240 Resolution Color LCD TFT Screen - Easy to use, one button is equivalent to one function (trigger, configuration, etc.) - Integrated multi-language interactive help - can communicate with SCPI protocol Isolated USB interface communication and software: The HANDSCOPE oscilloscope can be connected to a PC via a separate fiber optic USB. The standard configuration of SX-Metro data processing software can be used to view the graph on the storage file - display the real-time graph on the PC - control the oscilloscope via PC - store the graph in text format on the PC - output data in Execl format and Graph
Applications
Feature:
Feature:
Key indicators
product description
The oscilloscope OX 7062 is the ideal tool for laboratory testing and field testing.
The instrument is easy to operate and has direct access to all commonly used functions via 33 buttons. The OX 7062 is especially suitable for field use and is equipped with the latest patented “Plug and Play” probes. Each measurement channel is isolated and isolated from each other. It can be remotely controlled via a built-in WEB server and Ethernet. It's all in one, including a 2-channel TRMS multimeter.
Large 320 x 240 full color LCD display with detailed waveform detail and display of all measurements and functions. With the stylus, you can easily and quickly access the window menu: open, pull down or execute; the stylus can also directly act on graphical elements such as cursors, triggers and zooms.
Applications
Key indicators
Applications
This versatile childbirth simulator not only provides an excellent simulation of the normal delivery experience for the student and educator, but also provides instruction in abnormal and multiple deliveries.
It may be used for demonstration of the following obstetric procedures:
Now in one completely redesigned unit, the Life/form® Advanced Pelvic Examination and Gynecological Simulator is ideal for all aspects of gynecological education, training, and competency evaluation, including the bimanual exam, speculum exam, and cytology sampling. Students will appreciate the unprecedented realism of its internal and external features; while instructors will love the interchangeable components that make up its unique modular system. You choose the scenarios you want to teach! Components can be combined in a multitude of ways.
This simulator allows you the flexibility of customizing your scenarios with use of included makeup, blood, and thickener.
The Aggrameter utilizes the latest microwave and microprocessor technology to measure moisture content in various fine and coarse-grained materials. The prongs of the probe are inserted into the material to be tested and the percentage of moisture content is instantaneously shown on the easy to read display. The Aggrameter comes calibrated for both sand and aggregate, and can be programmed by the user for up to ten different materials. The Aggrameter can store more than 150 readings – complete with time and date for future reference.
The pycnometer is applied where there is an interest in knowing the specific weight.
Limitation: Temperature variations influence the measurements (can be prevented by climate control in the laboratory).
Saluran udara oropharyngeal dengan harga ekonomis, kode warna, bebas lateks. Tepi bulat halus meminimalkan trauma jaringan dan blok gigitan kuat mencegah oklusi. Mudah diidentifikasi! Kit berisi masing-masing: 50 mm (biru), 60 mm (hitam), 70 mm (putih), 80 mm (hijau), 90 mm (kuning), dan 100 mm (merah).
FEATURES |
● High quality Taut Band movement. |
FEATURES |
● Taut Band movement.
● Simple operation. ● Wiring check. ● Robust. ● Can be used on 2 wires L-E (ELCB/RCCB/GFCI tester). ● Can be used on 3 wires L-E-N (with wiring check). ● No battery required. ● Sense automatically 50 or 60 Hz. ● Current injected in phase with the voltage. ● Other voltage optional (110V). |
Bring anatomy lessons to life with this comprehensive set of 11 anatomical charts printed on heavy paper stock. Each laminated, 20" x 26" chart includes colorful, lifelike, detailed, labeled drawings covering the digestive, skeletal, respiratory, muscular, and male and female reproductive systems, as well as highlighting several additional organs, including the heart, brain, and more. Great for any science or health class
Great for patient and student education, this laminated chart (20" x 26") highlights the normal anatomy of the shoulder as well as common shoulder injuries. Features detailed and labeled illustrations that show the anatomy of the shoulder and injuries of the shoulder, such as a rotator cuff tear, dislocation of the humerus, bicipital tendonitis, and more. Printed on heavy paper stock. Perfect for healthcare professionals’ offices
A great teaching tool for dentists to use with patients and students, this chart uses detailed drawings to explain the anatomy of the teeth. Ideal for dental education, the chart is printed on heavy card stock and laminated.
Detailed and accurate, this laminated chart (20" x 26") clearly illustrates and labels the organs of the digestive system. The central image depicts the esophagus, liver stomach, gallbladder, pancreas, intestines, rectum, arteries, and veins. Additional anatomical drawings and explanatory text explain the roles of the different organs in digestion. Printed on heavy paper stock. Great for patient and student education.
Detailed and accurate, this masterfully produced, laminated chart (20" x 26") highlights the female reproductive system. Labeled illustrations depict an unfertilized ovum; the ovary, fallopian tube, uterus, and vagina; the female pelvic organs; the female perineum; and ovulation. Also includes additional information about the menstrual cycle and menopause.
Explaining the male reproductive system is simplified with this laminated chart (20" x 26"). Features detailed and labeled illustrations that show a sagittal section of the pelvic organ, anterior and posterior views of the system, a cross section of the penis, and more. Printed on heavy paper stock. Great for patient and student education.
With accurate details and labeling, this laminated chart (20" x 26") illustrates the complete respiratory system from the frontal sinus to the diaphragm. The central illustration shows the lungs and conducting system, while the surrounding illustrations depict detailed views of the paranasal sinuses, larynx, and more. Printed on heavy paper stock. Great for patient and student education
Features:
HDG6000B/HDG6000C series integrates multi-function like arbitrary waveform generator, pulse generator, 16-bit word generator, 7-digit cymometer and function generator; It can generate and output stable, accurate and low distortion signals; Built-in over 150 type arbitrary waveforms, which is easy to simulate various signals; Its large screen, user-friendly interface design and keyboard layout are convenient to use, the standard touch screen of HDG6000C series brings extraordinary experience to users; Rich standard configuration interfaces easily achieve remote control of the instrument.
* Output frequency range: 1uHz ~ 200MHz / 160MHz / 110MHz / 80MHz;
* Up to 1.25GSa/s sampling rate, 16bits vertical resolution to ensure the accuracy of the output waveform;
* Up to 64M memory depth, ensuring better waveform detail creation;
* Large and clear display screen (7.0-inch LCD color display, resolution up to 800x640), user interface is clear and intuitive;
* A rich set of modulation functions, support AM, FM, PM, 2ASK, 2FSK, 2PSK and PWM etc. ;
* 1uHz frequency resolution; minimum 2mv output amplitude;
* Built-in 7-digit high-resolution 200MHz cymometer; with optional higher performance cymometer;
* Standard communication interface: HDG6000B series: USB Host, USB Device, optional RS232 interface;
* Standard communication interface: HDG6000C series: USB Host, USB Device, LAN port, Wi-Fi, touch screen, optional RS232 interface;
* Built-in more than 150 arbitrary waveforms, including exponential rise, exponential drop, ECG signal, Gaussian, semi-positive, Lorentz, dual-tone multi-frequency, DC voltage, etc.
The manufacturing of these materials are required to meet standards set by ASTM and AASHTO to ensure that they fall within established limits and characteristics. Bituminous materials used in pavement require a much higher ductility than those used for less demanding applications, such as waterproofing or crack filling.
The Dean Stark moisture test apparatus is used to determine the water content in petroleum products, tars, emulsified asphalts and other bituminous materials by the distillation method. The distillation process allows the water in the test sample to be isolated and collected in the receiver of the trap. Dean Stark moisture test apparatus are available in both electric and gas configurations. Gas distillation traps can also be used to determine levels of volatile distillates.
Atterberg Limits (Liquid Limit Testing)
Liquid limit testing determines the water content at which soil changes from a liquid to a plastic state. It is determined using the devices on this page. To perform, a soil sample is placed into the cup of the liquid limit machine and separated into two halves using a grooving tool. The crank on the machine is then rotated so that the cup holding the sample strikes the base of the test machine. The number of blows is recorded until the two halves flow together and close the groove.
H-4234:
Recommended for performing liquid limit test in accordance with ASTM specifications. Includes 1 ea. of: H-4230 ASTM liquid limit machine, H-4930.250 mixing dish, H-4904 spatula, H-4915.025 graduated cylinder and a H-1350.3A 48 sample cans pack.
H-4235:
Same set as above except it has machine with counter. Includes 1 ea. of: H-4228 ASTM liquid limit machine, H-4930.250 mixing dish, H-4904 spatula, H-4915.025 graduated cylinder and a H-1350.3A 48 sample cans pack.
he ergonomic hand auger set for heterogeneous soils is used to carry out manual drilling and sampling in a great variety of different soils in an ergonomically sound way. It is particularly suitable for general soil investigation (description of the layering, geology, archaeology) as well as taking samples for such activities as environmental research. It can carry out drillings to a depth of 5 metres, depending on the depth of the groundwater, the build-up of the soil and the nature of the material to be drilled into.
For every type of soil above or under the groundwater table there is an auger type that is specifically suited to that situation. During the drilling process changes can be made from one type of auger to another without any problems.
Extensions can be added to the soil drilling system adding 50 cm with each additonal piece, which is also the difference in height of the working area.
This trainer is designed based on new VW Santana electronic fuel injection system, it allow the theoretical and experimental analysis of automotive electronic fuel injection system and perform demonstration of working principle and fuel injection of electronic fuel injection system ,fault detection and diagnosis, and troubleshooting etc .
<span "="" style="margin: 0px; padding: 0px;">-<span "="" style="margin: 0px; padding: 0px; font-size: 7pt; line-height: normal;"> <span "="" style="margin: 0px; padding: 0px;">The measuring panel adopts 4mm thick high-quality double-layer
<span "="" style="margin: 0px; padding: 0px;">aluminum composite materials as base plate, featured with firm and
<span "="" style="margin: 0px; padding: 0px;">durable, and is not easily deformed. laser-printed color circuit diagram,
<span "="" style="margin: 0px; padding: 0px;">surface covered by high-strength protective film, can maintain long time
<span "="" style="margin: 0px; padding: 0px;">without fading, with moistureproof, corrosion resistance and wear
<span "="" style="margin: 0px; padding: 0px;">resistance characteristics
<span "="" style="margin: 0px; padding: 0px;">-<span "="" style="margin: 0px; padding: 0px; font-size: 7pt; line-height: normal;"> <span "="" style="margin: 0px; padding: 0px;">The base of the training platform is welded with a steel structure, and the surface through paint process.
Amatrol’s AC/DC Electrical Learning Systems 1 and 2 (96-ADE1 and 96-ADE2) cover the fundamentals of electricity, such as electric measurement training and basic electrical circuit training, as well as inductance, capacitance, and transformers. Electricity is the most widely used utility and the demand will continue to increase as technology continues to grow. This means that more engineers and technicians will be needed to install, develop, and maintain electrical devices. These learning systems include a large array of industrial electrical power and control components, typical of what learners will find in real world applications. This hands-on experience is invaluable in today’s workplace.
The industrial components included with these learning systems are used with the heavy-duty welded steel workstation included with the Basic Electrical Training System (96-ADE1). This workstation features instrumentation, component mounting surface, component storage panel, and a built-in analog voltmeter. Each component’s leads are attached to quick-turn terminal posts, allowing learners to quickly connect components for a variety of circuit applications. Each learning system also includes an in-depth online electrical training course.
This Electrical training system covers the basic concepts of electricity, electrical measurements, and circuit analysis. This system includes various industrial quality components including a lamp module assembly, knife switch assembly, solenoid module assembly, fuse module assembly, circuit breaker module assembly, and much more! This system also includes a heavy-duty workstation with built-in power supply that allows learners to easily connect components and build hands-on skills.
The next Electrical training system (96-ADE2) adds onto the first system to expand a learner’s basic electrical skills including topics like inductance, capacitance, combination circuits, and transformers. This system includes a capacitor module assembly, relay module assembly, rheostat module assembly, and other industrial components. Learners will practice skills like testing a capacitor with a DMM, tracing the current path in a combination circuit, and calculating the current load on a transformer.
These electrical systems feature an expansive offering of electrical knowledge. Learners begin by studying very basic electrical topics such as defining electricity, describing alternating and direct electrical currents, and describing the operation of manual switches. Learners then move on to more advanced topics like voltage/current measurement, circuit protection devices, inductor and capacitor applications, voltage dividers, and transformer types. The online training courses are presented as interactive multimedia which includes audio, cutting-edge 3D animations and illustrations, and video.
Virtual simulations of electrical applications engage learners on a higher level by providing additional circuits and conditions under which learners can study. Learners can use the software to create and simulate circuits of their own design in addition to the circuits described by the exercises in the student learning materials.
Sample copies of the AC/DC Electrical 1 and AC/DC Electrical 2 Student Reference Guides are also included with the systems for your evaluation. Sourced from the multimedia curriculum, the Student Reference Guides take the entire series’ technical content contained in the learning objectives and combines them into one perfect-bound book. Student Reference Guides supplement this course by providing a condensed, inexpensive reference tool that learners will find invaluable once they finish their training making it the perfect course takeaway.
Flexible and modular-based system for learning basic electronics, basic electricity and circuit theory. The main advantage given is that the student establishes his own rhythm, thus rendering unnecessary to keep pace with the rest of the class.
kami menyediakan Seluruh Product EDIBON kami sebagai representative /DISTRIBUTOR DIINDONESIA
SILAHKAN HUBUNGI KAMI untuk penyusunan alat - alat praktek mahasiswa ,atau buka Link http://www.edibon.com/en
This unit is designed as a portable and self-contained service module for a wide range of accessories.
The bench is constructed from lightweight corrosion resistant plastic and is mounted on wheels for mobility. The bench top incorporates an open channel with side channels to support the accessory on test.
Volumetric measurement is integral and has been chosen in preference to other methods of flow measurement for its ease of use, accuracy and safety in use (no heavy weights for students to handle).
The volumetric measuring tank is stepped to accommodate low or high flow rates. A stilling baffle reduces turbulence and a remote sight tube with scale gives an instantaneous indication of water level. A measuring cylinder is included in the supply for measurement of very small flow rates.
A dump valve in the base of the volumetric tank is operated by a remote actuator. Opening the dump valve returns the measured volume of water to the sump in the base of the bench for recycling. An overflow in the volumetric tank avoids flooding.
Water is drawn from the sump tank by a centrifugal pump and a panel mounted control valve regulates the flow. An easy-to-use quick release pipe connector situated in the bench top enables the rapid exchange of accessories without the need for tools.
Each accessory is supplied as a complete piece of equipment needing no additional service items other than the F1-10 Hydraulics Bench. When coupled to the bench they are immediately ready for use.
This training unit demonstrates domestic refrigerator and freezers, self-contained air conditioning units and reverse cycle or heat pump systems.
Trainees and students in midwifery and obstetrics can practice correctly assessing the progress of the birth by palpating, using the birth stages trainer. By practicing on the birth stages trainer, the standard of clinical practice in midwifery and obstetrics can be considerably improved.
The trainer consists of a set of 6 inserts that show the level of cervical dilation and effacing. The inserts can be used both as stand-alone trainers and as an extension module for birth simulator P90. The inserts look the same from the outside, but indicate, using a number code on the back, the condition of the cervix on the inside.
The following levels and birth stages are shown:
Delivery contents:
Very realistic natural casting of three different female breasts in C and D cups, to train and practice breast examination.
One breast in this BSE model contains five palpable lumps, and the other breast, for comparison, has none. The BSE model's size makes it ideal for group demonstration.
FEATURES | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Transmitter
Receiver |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
SPECIFICATIONS | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
FEATURES | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Transmitter
Receiver |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
SPECIFICATIONS | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
The calcimeter by Eijkelkamp Soil & Water is suitable for the simultaneous determination of the carbonate content in 5 samples. Where possible the vulnerable glass was replaced by synthetic materials. Because hydrochloric acid is used a stable and ergonomic design was chosen. The calcimeter is delivered complete with reaction vessels and test tubes (without reagents).
Per reaction approximately one hour is required. Carbonates that are hard to dissolve, such as sea shells, take more reaction time.
The quantity of sample needed is determined beforehand by treating a part of the sample with hydrochloric acid on a watch glass. The carbonate content is estimated on the basis of the extend and the period of bubbling. Based on this estimate the quatity of sample for the analysis is determined.
With this calcimeter no balloon is used to keep the CO2 separate from the water (to prevent any gas from dissolving in the water). This results in much more accurate measuring results.
As a consequence of the repeatability and the accuracy, a series of measurements should be executed in a room in which there are no differences in temperature exceeding 4°C. In addition the reagents used must meet the standards for analysis. It should also be considered that other gasses (for instance in polluted soils) may be released. The gas will then have to be purified first and the CO2 will have to be determined otherwise.
- The bench adopts steel structure welding, surface coating processing. with four self-locking mechanism mobile directional
wheel, flexible to move and convenient to teach
- With teaching manual, it is suitable for car professional teaching and training institutions to use.
- Based on hydraulic brake system, include ac motor, front brake master cylinder, back brake master cylinder, brake master
cylinder, vacuum booster, brake disc, brake caliper, brake pipe, a pointer type pressure gauge, etc
- Can satisfy teaching requirement of automotive hydraulic brake system structure constitution and dynamic demonstration
- Use pointer type pressure gauge, can directly display each brake disc’s brake hydraulic pressure distribution and vacuum
pump air pressure value
Tests petroleum products to determine the amount of carbon residue left after evaporation and pyrolysis of an oil and to indicate relative coke-forming propensities. Includes burner, tripod, refractory block, nickel chrome triangle, nickel crucible and cover, Skidmore crucible, porcelain crucible and monel hood and bridge. Component parts available separately.
Listening to the sound of an unborn child which cannot be seen.
The Sakamoto cardiotocograph simulator 2 can be used for nurse and midwife training. Please note that the simulator does not provide a written or audio record of the heart rate.
Practice
1. Measure
2. Palpate
The baby is at 10 months. Four different presentation positions can be used for training.
3. Practice attaching
Practice can be carried out for securing the Doppler transducer and labor pain transducer belts. You can look at the box to check if the belts are attached correctly.
4. Listen to heartbeat
Practice listening to the fetal heartbeat at 4 points (No.1 breech presentation, No.2 breech presentation, No.1 occiput presentation and No.2 occiput presentation).
The heartbeat can be heard coming from the special box, and there are switches at the back for setting the heartrate and alarm.
The setting can be changed at a single touch to normal (120BPM), tachycardiac (>180 BPM) or bradycardiac (<110 BPM) heart rate. The alarm switch is set to ON, the alarm sounds when the Doppler transducer is incorrectly attached.
5. Look attaching at wave patterns
Four types of wave pattern (normal, tachycardiac, bradycardiac or transient bradycardiac) can be practiced.
Recording paper which is the same size as actual paper can be held in the hand while practising. (The recording paper is already printed on.) The recording paper can be inserted into the special box. The size of the recording paper is 15 cm x 60 cm.
Accessories included:
Fetus (for palpation), simulation Doppler transducer(x1), simulation labor transducer (x1), Doppler transducer fixing belt(x1), labor transducer fixing belt (x1), baby powder, foetal cushion,simulation recording paper (4 types), AAA batteries (x4), storage baghttps://youtu.be/snE3f5-vNxM
Our Advanced Catheterisation Trainer facilitates the teaching of urethral and supra-pubic catheterisation, as well as how to demonstrate self-catheterisation to patients (when using the optional Self Catheterisation Stand).
It has interchangeable accurate male and female anatomy, and both sets of genitalia are realistically soft and pliable.
The feel of the catheter passing along the urethra into the bladder corresponds closely to real life.
These simulators have been redesigned to be incredibly soft with a realistic feel and touch to enhance the birthing simulation experience. The newly revised three-dimensional simulators provide lifelike simulation of cervical examination prior to birth. Every effort has been made to provide exceptional realism so that the visual and tactile sensations experienced provide a positive transition to patient procedures.
The set consists of six separate 4" W x 4-1/4" H x 4-3/4" D pelvic blocks.
The external appearance of all six blocks is identical, with the variations being in the internal structure. The internal texture, tissue density, and correct anatomical size are all carefully represented to provide the most realistic condition possible. The simulators depict six different cervical conditions prior to birth.
Each is clearly identified on the back side to indicate which condition exists internally. Students will gain a tactile understanding of no dilatation, 2 cm, 5 cm, 7 cm, 9 cm, and effacement conditions.
Includes six simulation blocks (Stages One through Six), acrylic stand, glove, powder, lubricant, instruction card, and a hard carry case.
Three-year warranty.
Shipping Dimensions and Weight:
Electrical parameters | ||
---|---|---|
Power supply | Single phase AC 220V±10% or 110V±10%, 50/60HzAC | |
AC Voltage output | ||
range | 200mV, 400mV, 2000mV, 4000mV, 20V, 100V, 200V, 500V, 1000V |
|
Range 20V-1000V | Accuracy | ±(0.03%RD+0.02%FS) |
Stability | ≤0.01% FS /60s | |
Range 200mV-4000mV | Accuracy | ±(0.3%RD+0.2%FS) |
Stability | ≤0.04% FS /60s | |
Load capacity | 20VA | |
Waveform distortion | ≤0.3% | |
Adjustable Range | 0-120% FS (1000V not included) | |
Fineness | 5×10-5 | |
AC Current Output | ||
Range | 2mA, 4mA, 20mA, 40mA, 0.2A, 0.5A, 2A, 5A, 10A, 20A | |
Range 0.2A-20A | Accuracy | ±(0.03%RD+0.02%FS) |
Stability | ≤0.01% FS /60s | |
Range 2mA-40mA | Accuracy | ±(0.3%RD+0.2%FS) |
Stability | ≤0.04% FS /60s | |
Load capacity | 20VA | |
Waveform distortion | ≤0.3% | |
Adjustable Range | 0-120% FS | |
Fineness | 5×10-5 | |
Frequency Output | ||
Range | 45-65Hz | |
Fineness | 0.001Hz | |
Accuracy | 0.01Hz | |
Harmonic Wave | ||
Times | 2-31 | |
Extent | 0-20% | |
Each harmonic phase fineness | 0.01·N (N is harmonic order) | |
DC voltage output | ||
Range | 200mV, 400mV, 2000mV, 4000mV, 20V, 40V, 100V, 200V, 400V, 1000V |
|
Load capacity | 20W | |
Adjustable range | 0-110% FS (1000V not included) | |
Adjustable fineness | 5×10-5 | |
Stability | ≤0.01% FS /60s (peak-peak value) | |
Accuracy | ±(0.03%RD+0.02%FS) | |
Ripple wave | ≤1% FS | |
DC current output | ||
Range | 20uA, 40uA, 200uA, 400uA, 2mA, 4mA, 20mA, 40mA, 0.2A, 1A, 2.5A, 5A, 10A, 20A |
|
Load capacity | 20W | |
Adjustable Range | 0-110% FS (1000V not included) | |
Adjustable Fineness | 5×10-5 | |
Stability | ≤0.01% FS /60s (peak-peak value) | |
Accuracy | ±(0.06%RD+0.04%FS) | |
Ripple wave | ≤1% FS | |
Resistance box | ||
Range | 0-200Ω, 200-400Ω, 0-2kΩ, 2kΩ-4kΩ, 0-20kΩ, 20kΩ-40kΩ, 0-200kΩ, 200kΩ-400kΩ, 0-2MΩ, 2MΩ-4MΩ |
|
Fineness | 0.02% | |
Range 0-2kΩ, 0-20kΩ, 0-200kΩ | ||
Range 0-2kΩ | Adjustable Range | 0-100%FS |
Accuracy | ±(0.12%RD+0.08%FS) | |
Range 0-200Ω,0-2MΩ | Adjustable Range | 0-100% FS |
Accuracy | ±(0.3%RD+0.2%FS) | |
Range 2kΩ-4kΩ, 20kΩ-40kΩ, 200kΩ-400kΩ | ||
Range 2kΩ-4kΩ | Adjustable Range | 5%-100%FS |
Accuracy | ±(0.12%RD+0.08%FS) | |
Range 200-400Ω, 2MΩ-4MΩ |
Adjustable Range | 5%-100% FS |
Accuracy | ±(0.3%RD+0.2%FS) | |
Clamp meter range | ||
200A | Accuracy | ±0.2% |
600A | Accuracy | ±0.5% |
1000A | Accuracy | ±1% |
Dot frequency square wave output | ||
Range | 1kHz, 5kHz, 10kHz, 50kHz, 100kHz, 200kHz, 1000kHz | |
Square wave amplitude | 4.5V | |
Setting accuracy | 5×10-5 | |
Mechanical parameters | ||
Dimension (L×W×H) (mm) | 440x360x160 | |
Weight (kg) | 12 | |
Environmental conditions | ||
Operating temperature | 20°C±10°C | |
Relative humidity | ≤85%RH |
The CFPT Mk 3 is an anatomically accurate and tactile representation of the female pelvis. It is the ideal platform for hands-on examination as well as diagnosis of female conditions and minor pathologies. It can be used for many levels of training from undergraduate onwards, as well as in family health.
This female muscular figure displays human anatomy in a convenient size. This 84 cm high human muscular figure is perfect for demonstrations of human musculature and anatomy. Exquisitely hand-detailed and complete with 33 removable parts, this human muscular figure represents fine quality at a more affordable price. Painted by hand in realistic colors, this human anatomy model comes complete with stand and detailed multilingual product manual.
This human muscular figure includes the following removable parts:
Everything you need in one manikin! This dramatic, state-of-the-art training manikin is a complete resuscitation system designed for teaching life-saving techniques for infants. Ideal for pediatric advanced life support, nursing, hospital, paramedic, and EMT training at every level. Tactile and visual realism combine to provide students with the most realistic training possible. The most comprehensive PALS trainer available, the manikin allows practice of 4-lead ECG monitoring, IV therapy, umbilical catheterization, airway management, intraosseous infusion, and CPR - all in one manikin! The unique chest skin with an umbilical cord allows practice of proper techniques in umbilical catheterization, including cutting and clamping. Fluid may be aspirated through the umbilicus, making this training manikin incredibly lifelike. An IV arm and leg allow for realistic practice of pediatric venipuncture. The cephalic and basilic veins are accessible on the IV arm, as well as the dorsal venous arch on the hand, the great saphenous veins are accessible on the IV leg, as well as the dorsal venous arch on the foot. An intraosseous infusion leg demonstrates and simulates the intraosseous infusion procedure. Featuring realistic anatomy and size, the airway management head is ideal for practicing airway management skills on an infant. Includes a hard carrying/storage case. Five-year warranty.
Procedures That Can Be Performed:
CPR: Palpable and visual landmarks, fully articulated head, neck, and jaw, jaw thrust
Airway Management: Realistic anatomy of the mouth, tongue, oral pharynx, larynx, epiglottis, vocal cords, trachea, and esophagus, oral and digital intubation capabilities, suctioning capabilities
IV Arm & Leg: Smaller lumen tubing simulates the size of an infant's veins, realistic flashback from a pressurized system, replaceable skin and veins
ECG/Umbilical Cannulation Skin Arrhythmia recognition, learn proper techniques in umbilical catheterization, allows practice of umbilical cannulation, cutting, and clamping, aspirate fluid through the umbilicus
Intraosseous Infusion: Palpable landmarks include the patella, tibia, and tibial tuberosity, replaceable bones and skin, pressurized system allows aspiration of fluid
To be used with the Life/Form® Advanced Pelvic Examination and Gynecological Simulator (LF01235U). Includes one each of the following: Sexually Transmitted Diseases (STD) Module, Post-Menopause Module, Sexual Assault Nurse Examiner (S.A.N.E.) Module and Pre-Puberty Module.
The H-4236 cone penetrometer with dial indicator feaures a 6" (150mm) diameter dial gauge, which is easily readable and is graduated in 0.1mm divisions. Overall dimensions are: 8.6" x 6.7" x 16.1" (220 x 170 x 410mm)
The H-5236 digital cone penetrometer features an aluminum base with leveling screws and a spirit level for maintaining a level testing position. The digital readout provides readings in 0.1mm resolution in either mm or inches. The chromed support rod features micrometric vertical displacement for accurate positioning with a brass slider that provides smooth free fall, a stop and release button and an automatic zero set. Includes a stainless steel penetration test cone: 35mm long with a 30° angle, weighing 20g. Two brass cups are included (55 x 35mm and 70 x 45mm) This cone penetrometer can also be used to measure the shear undrained strength of undisturbed and reconstituted soil samples per CEN ISO/TS 17892-06. Overall dimensions are: 8.6" x 6.7" x 16.1" (220 x 170 x 410mm)
This core drill provides a flexible, multi-purpose vacuum/anchor bolt drilling system. It can be used for almost all applications involving floor, wall and ceiling placements, as well as hard-to-reach places. Includes a two-speed (350-900 RPM), 3.5 HP 20 amp heavy-duty motor, waterproof switch box, built-in water swivel, continuous duty oil-less vacuum pump, filter, hose, quick connections and has a 12-inch bit diameter capacity. The drill's 6" wheels provide easy maneuvering and its 10" (254mm) wide base is a vacuum pad anchor with more than 1000 pounds of vacuum force that solidly grips the drilling surface within seconds making it the ideal drill stand for floors, walls, ceilings, as well as, pavement. Requires water supply, if none is available order HR-2516 portable water pressure tank separately.
Requires water supply, if none is available order HR-2516 portable water pressure tank separately. Shipping wt. 85 lbs. (38.5kg)
Standard package includes:
• 3.5 HP Milwaukee electric drill motor with 2-speed gear box
• Water swivel
• Drill Stand with combination vacuum pad/anchor bolt base
• Large (6") rubber wheels
Specifications:
Horse power: 3.5
Motor: volts/amps: 115/20
Cycle: 50/60
Bit capacity: 12"
Auger capacity: NA
Column dimensions: 2.5" x 35"
Carriage travel: 22"
<table< p=""> </table<>
HR-2500 | |
---|---|
Horse power | 3.5 |
Motor: volts/amps | 115/20 |
Cycle | 50/60 |
Bit capacity | 12" |
Auger capacity | NA |
Column dimensions | 2.5" x 35" |
Carriage travel | 22" |
This core drill reduces job costs through the faster drilling speeds gained from the use of a gas-powered motor. This drill can be wheeled into place easily when mounted on its heavy-duty, sturdy platform or can also be mounted to a trailer, pickup or van.
Features include:
• 17 HP gas-powered, electric-start drill head with electric start, with 8" or 16" bit capacity
• Accurate and easy drill positioning and platform movement with its 4" Delrin wheels
• Dead-weight base no anchor bolts required
• Drill stand
Standard package includes:
• Drill stand
• 17 HP gasoline-powered, electric-start engine
• Variable RPM (300-1500 bit RPM)
• Water swivel
Manikin berkualitas profesional dengan harga murah! Desain komprehensif memungkinkan untuk latihan manuver Heimlich dan tekanan perut, serta CPR dan pernapasan mulut ke mulut. Penandaan anatomis yang realistis (jakun, arteri karotid, pusar, tulang rusuk, lekukan dada) memudahkan mempelajari penempatan tangan yang benar untuk memeriksa denyut nadi, melakukan kompresi dada, dan banyak lagi.
Memberikan umpan balik siswa yang berharga dan fitur penting lainnya:
Ideal untuk pelatihan kelompok - memungkinkan setiap siswa untuk memiliki manikin mereka sendiri untuk waktu latihan maksimum. Kepala yang mudah dibersihkan aman untuk dicuci dengan mesin pencuci piring dan mudah disanitasi. Tas paru bisa diganti. Dirancang untuk memenuhi kriteria American Heart Association untuk fitur manikin yang diinginkan. Dengan dial pemilih usia yang menyesuaikan piston kompresi dada untuk mempelajari teknik dewasa atau anak. Setiap set dikemas dalam tas nilon yang kuat dengan pasokan 50 kantong paru pelindung wajah dan alat penyisipan. Garansi lima tahun.
Manikin berkualitas profesional dengan harga murah! Desain komprehensif memungkinkan untuk latihan manuver Heimlich dan dorongan perut, serta CPR dan pernapasan mulut ke mulut
• Garansi lima tahun.
I. Current Transformer (CT) | II. Voltage Transformer (PT) |
---|---|
1. Magnetization curve | 1. Excitation characteristic test |
2. Transformation ratio test | 2. Transformation ratio test |
3. Polarity | 3. Polarity |
4. 5% and 10% error curve | 4. Ratio error, phases |
5. Current Injecting | 5. Degauss |
6. Degauss | 6. Calculation of knee point value |
7. Ratio error, phases | 7. Actual secondary load (burden), test (burden) |
8. Automatic calculation of excitation knee point value | 8. Resistance test |
9. Actual secondary load test (burden) (load test) | |
10. Resistance test | |
11. Secondary winding time constant (Ts) | |
12. Remanence coefficient (Kr) | |
13. Transient dimensioning factor (Ktd) | |
14. Peak instantaneous error (Er) | |
15. Magnetizing inductance (LU) |
Electrical parameters | ||
---|---|---|
Accuracy | 0.05%, 0.1% | |
Power supply | AC 220V±10% or AC 110V±10%, 50/60Hz | |
Excitation output voltage | 0-220Vrms | |
Excitation output current | 0-5Arms (20A peak-value) | |
Automatic frequency variation range | 0.1-60Hz | |
Equivalent excitation voltage | ≤5000V | |
Accuracy | ≤0.5% (0.2%RD+0.3%RG) | |
Secondary winding DC resistance measurement | Range | 0.1-300Ω |
Accuracy | ≤0.5% (0.2%RD+0.3%RG) | |
Secondary actual load measurement | Range | 5VA-1000VA |
Accuracy | ≤0.5% (0.2%RD+0.3%RG)±0.1VA | |
CT/PT phase error measurement | Accuracy | ±4min |
Resolution | 0.01min | |
CT ratio error measurement | Range | 1-30000 |
Accuracy | ≤0.5% | |
PT ratio error measurement | Range | 1-10000 |
Accuracy | ≤0.5% | |
Standards | ||
Reference standards | GB1207-2006, GB1208-2006, GB16847-1997 IEC60044-1, IEC60044-6, IEC61869-2-2012 |
|
Safety standards | GB 4793.1-2007 | |
EMC | EMC standard 89/336/EEC | |
FCC Subpart B of Part 15 Class A | ||
IEC 1000-4-2/3/4/6 | ||
Mechanical parameters | ||
Overall dimension (L x W x H) (mm) | 410 x 250 x 300 | |
Weight (kg) | ≤10 | |
Environmental conditions | ||
Relative humidity | 90RH% | |
Operating temperature | -10°C to +40°C | |
Altitude | ≤2000m |
The test items mainly include | |
---|---|
Steady | Transient |
excitation characteristic | secondary winding time constant (Ts) |
transformation ratio | remanence coefficient (Kr) |
polarity | transient dimensioning factor (Ktd) |
ratio error | peak instantaneous error (Er) |
phases | magnetizing inductance (LU) |
5% and 10% error curves | other parameters |
resistance | |
secondary load |
Equipment focuses on introduce the structure and principle of each components that
constitute the compression-type refrigerating system. Show the comparison of each kind
of throttling mode and the refrigerant quantity how to influence the Refrigeration effect.
Equipment refrigeration system mainly consists of compressor、heat exchanger、dry filter、
four kinds of throttling device、pressure protection switch、liquid view lens、high & low
pressure meter; Electrical system includes leakage protector、voltmeter、ammeter、digital
display thermometer. Equipment equipped with four universal wheels, convenient for
moving
Equipment Training Project
1) Understand the main components of refrigeration system
2) Understand the principle and function of refrigeration system main components
3) Understand the working principle of refrigeration system
4) Understand the control principle of electrical system
5) Pressure maintaining and detecting of refrigeration system
6) Vacuumize of refrigerating system
7) Method for charging refrigerant and judgement
8) Comparison training of refrigeration system various throttling way
9) Influence of refrigerant quantity to refrigeration effect
10) Understand the judgement method that refrigeration system do not work or
refrigeration effect not good
The Fluke Calibration 732C DC Voltage Reference Standard is a RoHS compliant direct voltage reference used to maintain the volt in primary and secondary standards laboratories. Individual 732C voltage standards provide 10 V, 1 V, and 0.1 V outputs and may be transported easily to remote locations while the dc reference is maintained in the laboratory. The 734C DC Voltage Reference Standard consists of four electrically and mechanically independent 732C DC Reference Standards and a rack-width enclosure. Two model families, Base and Select, differ in that the Select models are two times more stable than the Base models.
Because each 732C in the 734C DC Reference Standard is based on the same architecture pioneered in the popular 732A DC Voltage Standard—the first standards lab quality 10 V electronic reference—you can rely on it to provide the same high stability and predictable drift rate you’ve come to expect, in a smaller, more portable package identical to the 732B DC Voltage Standard. The 734C is also compatible with 732B DC standards and can support any combination of 732 B and C models. Similarly, 734A can be used with the newer 732C voltage standards, providing the ultimate flexibility and maximizing asset utilization.
To simplify support of your 734C, Fluke Calibration offers a variety of calibration services to assign values and predicted performance for each of the 10 V outputs, traceable to national standards and to the Fluke Calibration 10 V Josephson Array.
With the 734C, it is remarkably simple to establish and maintain a primary voltage standard in your laboratory. Over time, with frequent intercomparisons of your four units, and regular calibrations of one or more units, you can reduce the uncertainty of your 734C by a factor of three.
From 1984 until the acquisition of our Josephson Array, the Fluke Calibration Primary Standards Laboratory maintained its corporate volt in this manner, reducing the absolute uncertainty to ± 0.35 μV/V traceable to national standards.
The 1 V and 0.1 V are key calibration / verification points for digital multimeters. Thanks to the high-precision thin-film resistive networks, which are manufactured in Fluke’s own thin-film fab facility, the 734C now comes standard with those two additional outputs. It eliminates the need for external dividers, making the measurement setup easier and less prone to errors.
Fluke Calibration offers Select models for customers requiring primary standards lab capability for calibrating demanding workloads and gaining independence from sending standards to other labs for calibration. The process of calibration is the same for both the Base and the Select models. The only exception is that the Select models (732C/S/C or 734C/S/04) are compared to Fluke Calibration J-array for 180 days of drift characterization data and provide two times better stability at 10 V. This process ensures the selection of the best possible standards meeting stringent drift performance requirements.
Fluke Calibration provides the products and services you need to manage your traceability requirements. Fluke Calibration performs an output voltage calibration on a new 732C by comparing it against its own J-array maintained at the factory. The base model 732C is shipped COLD (“not powered”) and comes with a voided calibration certificate demonstrating its operability. The owner is responsible for providing traceability as required locally.
Accredited calibration and drift characterization data comes standard with 732C units ordered to ship “HOT” (powered on). During manufacturing, each 732C is compared to Fluke Calibration direct voltage standards for at least 90 days to obtain the drift characterization data. Once the drift rate is known, the 12-month projected output voltage is determined. The units are then shipped under power. The continuous power-on condition is required during shipment through delivery to your lab for the calibration to remain valid. If continuous power is not maintained, then the validity of the calibration may be compromised. Contact your Fluke Calibration representative to determine if the 732C alternatives are available in your area.
A four-unit voltage reference standard is desirable any time you need to maintain and disseminate a reference voltage. At a minimum, three units are intercompared to detect and identify changes in the output of any one cell. A fourth unit may be used as a spare or to transport the volt to or from remote locations. When it returns to the laboratory, it can be compared to the other three to determine if its output has shifted during transport.
However, there is more to a four-unit reference. According to NBS Technical Note 1239, published by the U.S. National Bureau of Standards (now NIST) in 1987, four to six references are required to provide measurement integrity and redundancy, and to minimize the number of measurements required. References must be completely independent of one another. Otherwise, common elements, such as a power supply or oven, might affect the correlation of reference outputs. In addition, with frequent intercomparisons of four units, you can detect when any one of the units begins to drift beyond specifications or needs to be repaired.
Each 732C is a stand-alone dc standard with its own power supply, oven, supporting electronics and packaging. Each may be purchased separately, or as a full 734C system, which includes four 732Cs that slide into a rack-width enclosure.
Combined with 742A-1 and 742A-10k Resistance Standards, a single 732C makes a robust and compact Artifact Calibration support package for instruments such as the Fluke 5730A High Performance Multifunction Calibrator and Fluke 8508A Reference Mulitmeters, including the older generation 5700A and 5720A models.
Standards laboratory operations have changed. In the past, people brought their workload to the standards lab. Today, the functions of the standards lab are being distributed, requiring that many calibrations be performed in the field. The 734C, and its electrically and mechanically independent 732C Standards, are designed to meet that need. The voltage reference remains undisturbed in your laboratory, while at the same time you can distribute the volt to remote locations outside the lab. When the unit is returned to the lab, comparisons can be made to the reference to determine if a shift has occured during the transfer. To maintain traceability to national standards, one unit may be transported to a national lab or other primary standards lab for calibration, again, without disturbing the reference. Each 732C Standard is relatively light, weighing just 5.9 kg, and its 72-hour battery life provides ample capacity for long shipments. An optional external battery extends that capacity to 210 hours. A special transit case, designed to hold one 732C and an external battery, simplifies transport even further.
The 732C can stand up to a lot of abuse. The outputs can be shorted indefinitely and the 10 V output is protected up to 1100 V dc, 25 mA, without damaging the unit or affecting its output.
Fluke provides two service options: For existing Fluke 732As, 732Bs or 732Cs or similar dc reference standards that are already in use, the Direct Voltage Maintenance Program is a service where Fluke Calibration can provide calibration certificates for these standards. This service consists of two calibration alternatives that can be used depending on your needs.
Calibration certificate services can be easily performed on voltage referrence standards returned to Fluke Calibration service facilities. Contact your Fluke Calibration representative or your local Fluke service center for details regarding these calibration certificate alternatives.
With the Direct Voltage Maintenance Program (DVMP) 732C-200 services, a voltage reference standard owned and calibrated by Fluke Calibration, including all necessary connecting cables and operating instructions, is sent to your site for comparison with one or more of your own reference standards. You make a series of readings over several days and forward the standard to the Fluke Calibration Standards Laboratory. A value for your reference relative to the Fluke standard is assigned. Within one week, a preliminary Report of Calibration is returned to you. Once the standard is returned to Fluke Calibration, it is compared to the Fluke Voltage Reference Standard. A final value is assigned to your reference, and a final Report of Calibration is sent to you. The 732C-200 service provides a calibration certificate for one local standard.
The Deluxe Child CRiSis™ Manikin is a dramatic, state-of-the-art manikin designed for teaching individuals or groups life-saving techniques for children. Simulating an 5-year-old child, manikin provides complete PALS training capabilities, it combines all of the skill stations on one manikin, making training more realistic and giving students an appreciation for the smaller scale of the patient. The Life/form® Child CRiSis™ Manikin also includes an Arrhythmia Simulator. This arrhythmia/pacing simulator recreates 17 adult heart rhythms and 17 pediatric rhythms. With an external pacer, you can simulate electronic capture. You can also simulate cardioversion with manual, semiautomatic, or automatic defibrillation.
This anatomically correct in detail. Realistic anatomy and landmarks include a mouth, tongue, oral pharynx, epiglottis, arytenoids, vocal cords, trachea, and esophagus. In addition to the palpable and visual landmarks, the head, neck, and jaw are fully articulated, allowing a realistic jaw thrust feature. This manikin has separate left and right lungs for auscultation, has oral, nasal, and digital intubation capabilities, and includes an inflatable stomach bladder to indicate esophageal intubation. Also features E.T., E.O.A., P.T.L., L.M.A., E.G.T.A., Combitube®, and King System insertion. The Child CRiSis™ Manikin is 46-3/4 in. L and weighs 20 lbs. Ideal for ACLS, nursing, paramedic, and EMT training at every level. Hard carry case (LF03467U) is available separately.
Blood Pressure Arm
Auscultatory gap can be added
Can be used with optional speaker system to broadcast sounds to the entire classroom (LF01189U)
Instructor determines systolic and diastolic levels, heart rate, and sound volume
Palpable radial pulse
Speaker in arm reproduces real blood pressure sounds
5 Korotkoff sounds
CPR
Fully articulated head, neck, and jaw
Jaw thrust
Palpable and visual landmarks
Palpable carotid pulse (manual)
Defibrillation Chest
Arrhythmia recognition
Completely compatible with all standard brands and types of defibrillators, monitors, and patient simulators
Load box prevents shocks from going to the patient simulator
Manual, automatic, and semi-automatic defibrillation
Pacing
Rhythms are detected at 4 ECG sites and 2 defibrillation sites
Femoral Access
Articulated leg requires proper positioning
Palpable arterial pulse (manual)
Palpable symphysis pubis and anterior superior iliac spine
Realistic flashback from pressurized venous system
Replaceable injection pad
Intraosseous Infusion
Palpable landmarks include the patella, tibia, and tibial tuberosity
Pressurized system allows aspiration of fluid
Replaceable bones and skin
IV Arm
Articulated at the biceps for antecubital and dorsal access
Realistic flashback from a pressurized system
Replaceable skin and veins
Smaller lumen tubing simulates the size of a childs veins https://youtu.be/LXGsjLNFYe8
This anatomy model is a representation of a median section through the female pelvis at 40 weeks pregnant with a removable fetus. Study the normal position of child before birth with this model plus the human reproductive and urinary systems. A uterus with embryo in 3rd month of pregnancy is mounted on base for added detail. The realistic and high quality female pelvis includes the female genital organs and other important anatomical details. This pregnancy female pelvis is a great addition to any anatomy classroom or doctor's office to educate about the stages of pregnancy.
Dimensions: 15.0 x 9.8 x 15.7 in
Weight: 5.51 lb
This compact Desktop Trainer Female Pelvic Organs Model illustrates the position the IUD assumes once inserted correctly into the uterus.
Desk Top Trainer Female Pelvic Organs I Features:
FEATURES | |||||||||||||||||||||||||||||
● Microprocessor-controlled. ● Four insulation test voltages. ● Insulation resistance; auto ranging on all ranges. ● Bargraph indicates test voltage; rise and decay can be observed during tests. ● Visual and audible warning if external voltage is present. ● EnerSave™ feature to extend battery life. ● 2 Lines × 16 characters large LCD. ● Low battery consumption. ● Low battery indicator. ● Overload protection. ● Auto-off. ● Show test time duration (up to 99.9s) for easy comparison. ● EEPROM calibration. ● Built-in carry case and test leads in separate pouch. |
|||||||||||||||||||||||||||||
SPECIFICATIONS | |||||||||||||||||||||||||||||
|
FEATURES | ||||||||||||||||||||||||||
● Microprocessor-controlled. ● Four insulation test voltages. ● Insulation resistance; auto ranging on all ranges. ● Bargraph indicates test voltage; rise and decay can be observed during tests. ● Visual and audible warning if external voltage is present. ● EnerSave™ feature to extend battery life. ● 2 Lines × 16 characters large LCD. ● Low battery consumption. ● Low battery indicator. ● Overload protection. ● Auto-off. ● Show test time duration (up to 99.9s) for easy comparison. ● EEPROM calibration. ● Built-in carry case and test leads in separate pouch. |
||||||||||||||||||||||||||
SPECIFICATIONS | ||||||||||||||||||||||||||
|
FEATURES | ||||||||||||||||||||||||||||||||||||||||
● Microprocessor-controlled. ● Four insulation test voltages. ● Insulation resistance; auto ranging on all ranges. ● Measures insulation time test. ● Bargraph indicates test voltage; rise and decay can be observed during tests. ● Visual and audible warning if external voltage is present. ● EnerSave™ feature to extend battery life. ● 2 Lines × 16 characters large LCD. ● Low battery consumption. ● Low battery indicator. ● Overload protection. ● Auto-off. ● Show test time duration (up to 99.9s) for easy comparison. ● EEPROM calibration. |
||||||||||||||||||||||||||||||||||||||||
SPECIFICATIONS | ||||||||||||||||||||||||||||||||||||||||
|
FEATURES | ||||||||||||||||||||||||||||||||||||||||||||
● Microprocessor-controlled. ● Four insulation test voltages. ● Insulation resistance; auto ranging on all ranges. ● Measures insulation time test. ● Bargraph indicates test voltage; rise and decay can be observed during tests. ● Visual and audible warning if external voltage is present. ● EnerSave™ feature to extend battery life. ● 2 Lines × 16 characters large LCD. ● Low battery consumption. ● Low battery indicator. ● Overload protection. ● Auto-off. ● Show test time duration (up to 99.9s) for easy comparison. ● EEPROM calibration. |
||||||||||||||||||||||||||||||||||||||||||||
SPECIFICATIONS | ||||||||||||||||||||||||||||||||||||||||||||
|
FEATURES | |||||||||||||||||||||||||||||||||||||||||
● Microprocessor-controlled. ● Four insulation test voltages. ● Insulation resistance; auto ranging on all ranges. ● Bargraph indicates test voltage; rise and decay can be observed during tests. ● Visual and audible warning if external voltage is present. ● Fully protected: crow bar. ● Carry case. ● EEPROM calibration. |
|||||||||||||||||||||||||||||||||||||||||
SPECIFICATIONS | |||||||||||||||||||||||||||||||||||||||||
|
FEATURES | |||||||||||||||||||||||||||||||||||||||||
● Microprocessor-controlled. ● Four insulation test voltages. ● Insulation resistance; auto ranging on all ranges. ● Bargraph indicates test voltage; rise and decay can be observed during tests. ● Visual and audible warning if external voltage is present. ● Fully protected: crow bar. ● Carry case. ● EEPROM calibration. |
|||||||||||||||||||||||||||||||||||||||||
SPECIFICATIONS | |||||||||||||||||||||||||||||||||||||||||
|
FEATURES | |||||||||||||||||||||||||||||||||||||||||
● Microprocessor-controlled. ● 2 ×16 characters; large intelligent LCD module. ● 20 Insulation test voltages 500V, 1kV, 1.5kV, 2kV, 2.5kV, 3kV, 3.5kV, 4kV, 4.5kV, 5kV, 5.5kV, 6kV, 6.5kV, 7kV, 7.5kV, 8kV, 8.5kV, 9kV, 9.5kV, 10kV. ● Ener-Save™ feature to extend battery life. ● Bargraph indicates test voltage; rise and decay can be observed. ● Visual and audible warning if external voltage is present(>500Vac or Vdc.) ● Insulation resistance; auto-ranging on all ranges. ● Overload protection. ● Low battery indicator (read time battery voltage measurement). ● Measures insulation time duration of the test. ● Low battery consumption. ● Better than 10% accuracy on all ranges. ● Auto-off. |
|||||||||||||||||||||||||||||||||||||||||
SPECIFICATIONS | |||||||||||||||||||||||||||||||||||||||||
|
FEATURES | |||||||||||||||||||||||||||||||||||
● Microprocessor-controlled. ● 2 ×16 characters; large intelligent LCD module. ● 20 Insulation test voltages 500V, 1kV, 1.5kV, 2kV, 2.5kV, 3kV, 3.5kV, 4kV, 4.5kV, 5kV, 5.5kV, 6kV, 6.5kV, 7kV, 7.5kV, 8kV, 8.5kV, 9kV, 9.5kV, 10kV. ● Ener-Save™ feature to extend battery life. ● Bar-graph indicates test voltage; rise and decay can be observed. ● Visual and audible warning if external voltage is present (>500Vac or Vdc.) ● Insulation resistance; auto-ranging on all ranges. ● Overload protection. ● Low battery indicator (read time battery voltage measurement). ● Measures insulation time duration of the test. ● Low battery consumption. ● Better than 10% accuracy on all ranges. ● Auto-off. ● Calculates Dielectric Absorption Ratio (DAR) automatically. ● Calculates Polarization Index (PI) automatically. |
|||||||||||||||||||||||||||||||||||
SPECIFICATIONS | |||||||||||||||||||||||||||||||||||
|
FEATURES | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
● Microprocessor-controlled.
● Indicates phase rotation. ● Indicates phase presence. ● Tests for disconnection sensitivity. ● Indicates battery status. ● Tests for disconnection time. ● Measures voltage phase to earth. ● Select one of 3 Phase to test ELCB. ● Color-coded test leads. ● Phase presence indication from as low as 100Vac. ● Very low consumption. ● Fused earth leakage tester. ● ELCB works 50Vac to 330Vac 50Hz / 60Hz. ● Led indication of Voltage on ELCB. ● Phase rotation and presence does not require battery to indicate. ● EN 61010-1 CAT III 550V. EN 61326-1 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
SPECIFICATIONS | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|